3 Mode of operation – Fuel quality requirements
37
N
OMINAL
THERMAL
VALUE
DEPENDING
ON
WATER
CONTENT
The following table indicates the maximum nominal thermal value
depending on water content, in reference to the fuels approved for
the HDG Compact 25 - 80 in accordance with DIN EN 14961 "Solid
biofuels - fuel specifications and classes".
Wood chips
P31.5, M20, A1.0
(A1.5) or
Pellets A1, A2
Wood chips P45,
M25, A1.0 (A1.5)
Shaving briquet-
tes A1, A2, D60,
L50
Planing/saw sha-
vings A1, A2, M20,
A1.0 (A1.5)
HDG Compact 25
31 kW
-
-
-
HDG Compact 35
31 kW
-
-
-
HDG Compact 45
45 kW
43 kW, (42 kW)
43kW
42 kW, (40 kW)
HDG Compact 50
50 kW
48 kW, (47 kW)
48 kW
47 kW, (45 kW)
HDG Compact 65
65 kW
63 kW, (62 kW)
63 kW
62 kW (60kW)
HDG Compact 80
80 kW
78 kW, (77 kW)
78 kW
77 kW, (75 kW)
Table 3/7 - Max. nominal thermal value depending on water content
Summary of Contents for Compact 25
Page 1: ...hdg bavaria com HDG Compact 25 80 Operation Manual ...
Page 2: ......
Page 186: ...12 Index 186 HDG Compact 25 35 Version 2 de HDG Bavaria GmbH Oktober 2007 ...
Page 187: ......