USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
21
Cell Selection
Your model AquaRite S3 has been shipped with its corresponding TurboCell. Select that model Tur-
boCell that will be used and press “OK” to advance to the next screen.
Pump Scan
After selecting the TurboCell, the AquaRite S3 will look for a connected filter pump by scanning its
communication connection. If a Smart Relay is found, it will configure operation for a single speed
filter pump. If a VSP is found, it’ll configure operation for a variable speed pump. If no device is found,
it’ll assume that the AquaRite S3 will not be controlling a filter pump and enable/disable chlorine
generation based on the flow switch.
It’s important that your VSP or Smart Relay be powered on during this discovery period. If the
AquaRite S3 does not discover a connection, you can rescan the communication connection by
pressing the “+” button. If the AquaRite S3 does not see your pump or Smart Relay, check for power
at the device and make sure the low voltage communication connection is correct and secure.
Heater
Select whether a heater is connected to the AquaRite S3. Note that a heater requires the use of a
water temperature sensor sold separately.
Air Temperature Sensor
Select whether you have an air temperature sensor connected to the AquaRite S3. An air tempera-
ture sensor is required for recirculation freeze protection.
Firmware Upgrade
The AquaRite S3’s firmware is the basic operating system that runs the unit. The AquaRite S3 was
shipped with the version of firmware that was available at the time of release. There may be a newer
version available and if so, we encourage you to upgrade. Also, if you have experienced problems,
Hayward Technical Support may advise you to upgrade your AquaRite S3 firmware. To upgrade the
AquaRite S3 firmware, prepare a FAT32 formatted USB thumbdrive. Make sure there are no files or
folders on the drive. Always copy files directly to the root of the drive. Follow the procedure below.
1. Go to www.hayward.com, locate the AquaRite S3 product page and download the latest firm-
ware version to your USB thumbdrive. Firmware is available separately for the unit’s Display and
Mainboard. Download both files.
2. Remove power to the AquaRite S3.
3. Remove front panel and locate USB connector shown on page 4.
4. Insert the USB thumbdrive into the USB port.
5. Apply power to the AquaRite S3.
6. At the home screen, press “OK” and navigate to “System settings” -> ”Service settings” ->
”Service Mode” -> ”Firmware update”. You’ll see “Display” and “Mainboard”. Update both
separately, making sure to select the corresponding file on the thumbdrive.
7. After firmware has been updated, the AquaRite S3 will return to the home screen. Power down
the unit and remove the thumbdrive. Replace the cover and power up the AquaRite S3. Con-
figuration and operation settings should not be affected and the unit should resume normal
operation.