USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
10
High Voltage Wiring
Input Power
If the AquaRite S3 will be controlling a VSP or single speed pump using a Smart Relay, it must be
powered continuously. A schedule will be created for the pump and the AquaRite S3 will generate
chlorine only when the pump is running. If the AquaRite S3 will not be controlling the filter pump, it
should be wired to the load side of the pump timer or in parallel with the filter pump. This will ensure
that the AquaRite S3 will power up with the pump and only generate chlorine when the pump is run-
ning. If not wired in that manner, the flow switch will enable/disable the chlorinator function.
Power Connection
The AquaRite S3 can be powered by 115 VAC (2A) or 230 (1A) VAC. There is no need to manually
select or use different input terminals, the AquaRite S3 will automatically detect the input voltage.
A
wiring harness is included and will plug into the input power connector shown below. Wire nuts are
supplied for connecting the harness to input power. Wire the harness according to the diagram below.
Connect the ground wire to one of the green ground screws as shown.
For Canadian installations, the AquaRite S3 shall be connected to a circuit protected by a class A
ground fault interrupter.
for 115 VAC use black (L1) and gray (N)
or
for 230 VAC use black (L1) and gray (L2)
Ground