USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
24
Super Cl.
When you have an unusually high bather load, a large amount of rain, a cloudy water condition, or
any other condition that requires a large amount of chlorine to be introduced to the pool, enable
the super chlorinate function and select the desired hours. If the AquaRite S3 controls the filter
pump (either VSP or single speed using a Smart Relay), it will turn the pump on and set the chlorine
generator to maximum output. The super chlorinate function will continue for the programmed time
period overriding the normal filter pump schedule settings. At the end of the super chlorinate period,
the pool will return to normal operation. If you manually turn off the filter pump, the super chlorinate
function terminates.
If the AquaRite S3 does not control the pump, activating super chlorinate will only set the chlorina-
tor to maximum output for the programmed time period. The chlorinator can only generate chlorine
while the pump is running so be sure to run your pump continuously during this time. If the AquaRite
S3 is turned off during the super chlorination period, it will not resume operation and return to the
previous level settings.
The Diagnostics menu offers specific technical information about the AquaRite S3’s operation. Values
are shown in the following windows:
•
Cell Temperature
- this is the temperature inside of the cell and should be the same as the
return water temperature after the heater.
•
Instant PPM
- this is the salt concentration in the cell read at that moment. Any changes to the
pool’s salt level will be seen instantly.
•
Average Salt
- this is the salt concentration averaged over a period of time.
•
Cell Current
- To generate chlorine, electrical current must flow through the cell. The actual
current reading (amps) is displayed here. If this reading is 0A, chlorine is not being generated at
that moment.
•
Cell Type
- this window shows the model cell that was selected during configuration.
•
Relay Pol.
- To prevent scaling and increase cell life, the AquaRite S3 switches polarity periodi-
cally. This window shows the polarity at that moment.
•
Cell Voltage
- This is the voltage that is being applied to the cell.
Filter pump Menu
If the AquaRite S3 discovers a VSP (variable speed pump) or Smart Relay (single speed pump) during
configuration, it will add a Filter Pump menu to the Main Menu. The Filter Pump menu is the same
for both pumps except that the menu will allow you to set a speed for the VSP. This setting doesn’t
exist for a single speed pump.
State
Use the “+” and “-” buttons to enable or disable the filter pump.
Press “OK” to save the selection.
Speed (only shown for VSPs)
Use the “+” and “-” buttons to select LOW, MEDIUM and HIGH set-
ting. Press “OK” to save the selection. To set the actual speeds for
each setting, refer to the “Filter Pump” section on page 28.
Freeze prot (requires Air Temperature Sensor)
Use the “+” and “-” buttons to enable or disable the freeze protec-
tion. Enabling recirculation freeze protection will automatically turn
the pump on when the air temperature drops below the “Freeze
ºF