USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
28
1.
Cell type
- Your model AquaRite S3 has been shipped with its corresponding TurboCell
which should have been selected during configuration. If a mistake was made or if the
TurboCell was replaced with a different model, make the selection here using the “UP”
and “DOWN” buttons, then press “OK” to save.
2.
Filter Pump
-
For VSPs, set speeds for Low, Medium, High and Freeze Protection.
These are the speeds that the pump will run for each setting. To set speeds:
• Press “UP” or “DOWN” buttons to highlight the speed setting you’d like to change.
• Press “+” or “-” change value. Use “UP” or “DOWN” buttons to change columns.
• Press “OK” to save the new value.
• Press “OK” to apply the new speed setting.
3.
System config
-
Enable/disable or change the following configuration items:
•
Remote -
Set mode to Master (default) or Remote (controlled by an Hayward
Omni automation control). See “Remote Operation” below for more information.
•
Heating
- Use the “+” and “-” buttons to enable/disable the heater. Press “OK”
to save.
•
Body of water
- Use the “+” and “-” buttons to toggle between pool and spa.
Press “OK” to save.
•
Air temp.
- Use the “+” and “-” buttons to enable/disable the air temperature
sensor. Press “OK” to save. The AquaRite S3 will display the air temperature and
use it for recirculation freeze protection by turning on the pump when the air tem-
perature drops below the freeze protection temperature which is set separately.
•
Low salt (1200ppm default)
- when the salt level is lower than this adjustable
value, the AquaRite S3 will show a warning.
•
Very low salt
(800ppm default)-
when the salt level is lower than this adjustable
value, the AquaRite S3 will shut down.
4.
Devices
-
Use this selection to search for connected devices. If a VSP or Smart Relay
is found, toggling it to “YES” will set the device to the Filter Pump. Any device found
that is not a VSP or Smart Relay will be forced to “NO”.
•
Factory Reset settings
- Press “OK to reset previous settings. Confirm by pressing “OK” again,
or cancel by going “BACK”. Note that all chlorination, pump and heat settings will be deleted.
These settings will have to be reentered to resume proper function.
•
Reset cell
- Use this selection to reset TurboCell after cleaning or replacement.
•
Service mode
- View status of the following:
1.
Chlorination
- view various parameters including cell temperature, cell type, relay
polarity, cell current, cell voltage, chlorination setting. This screen will also allow you
to manually change polarity, enable super chlorination and change the chlorination
setting.
2.
Sensors
- view the state and temperatures of all connected sensors.
3.
Relays
- view the state of configured relays.
4.
Pump
- view the pump status and pump speed.
5.
Upgrade Firmware
- Refer to page 21 for information on this function.