USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
7
Mounting the Equipment
AquaRite S3 Enclosure
The AquaRite S3 is contained in a raintight enclosure that is suitable for outdoor mounting. The
control must be mounted a minimum of 6 ft. (2 meters) horizontal distance from the pool/spa (or
more, if local codes require). The AquaRite S3 is designed to mount vertically on a flat surface with
the knockouts facing downward. Because the enclosure is vented (disperses heat from inside the
box), it is important not to block the four sides of the control. Do not mount the AquaRite S3 inside a
panel or tightly enclosed area. Plugs are supplied to seal any unused knockouts.
When selecting a mounting location, note that the standard cables supplied with the included flow
switch and TurboCell, as well as optional accessories like Hayward temperature sensors, are all 15
ft. (5m) long. Try to mount the AquaRite S3 at a height/location where the screen and keypad can
be easily used. Select the proper mounting hardware given the size and weight of the unit. The
AquaRite S3 mounting brackets require a total of 4 mounting screws/bolts to fasten the AquaRite S3
to the mounting surface.
Temperature Sensors (sold separately)
If using the heater function or the recirculation freeze protection function, the AquaRite S3 will require
the use of Hayward temperature sensors. Refer to the following information for mounting instructions.
Water Sensor (required for heater control)
This sensor is used to measure the pool/spa temperature and is installed in the filtration plumbing
after the filter but before either the solar or conventionally fueled heaters—refer to the plumbing
overview diagram.
1. Drill a 3/8” (10mm) diameter hole in the PVC piping and remove all chips and burrs.
2. Insert sensor until O-ring collar sits flush on the hole.
3. Position hose clamp over the sensor and gently tighten until O-ring makes an adequate seal.
Do not overtighten.
Air Sensor (required for recirc freeze protection)
Mount the air sensor outdoors to a surface with low thermal conductivity. IMPORTANT: The air sensor
must not be mounted in direct sunlight.