12/24/07
888-2685-001
3-15
WARNING: Disconnect primary power prior to servicing.
Section 3 Operation and Adjustments
Ranger Commissioning Manual
3.7
Output Main Menu
If you press the Output button on the control panel
overlay, or the Output button on the HOME screen, it
will take you to the screen shown in Figure 3-12. The
Output Menu Tree is shown in Figure 3-31 on page 3-33.
Figure 3-12 Output Screen
This screen is broken into 3 main areas:
a.
Output Faults - This panel lists the 6 possible output screen faults. A fault would
cause one or more to be highlighted in red while a warning condition would high-
light yellow.
1.
VSWR - VSWR has exceeded fault threshold of 1.9:1
2.
Foldback - VSWR has exceeded foldback threshold of 1.4:1 (VSWR fold-
back is accomplished automatically by reducing the exciter power).
3.
RF Monitor Communications - A warning condition stating that the RF
Monitor board is not communicating over the CAN bus to the Main Con-
troller.
4.
PA Circulator 1 or PA Circulator 2- the power to the circulator reject load
has exceeded 400W. The RF Monitor board is calibrated to give a 3 Vdc
detected sample when the output from the reject attenuator is 40mW (40dB
below 400W).
5.
PA 1&2 Reject - the power to the combiner reject load has exceeded 400W.
The RF Monitor board is calibrated to give a 3 Vdc detected sample when
the output from the reject attenuator is 40mW (40dB below 1kW).
To Figure 3-13
To Figure 3-3
Control
External RF Switch
Summary of Contents for Ranger Series
Page 4: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing MRH 2...
Page 5: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Page 7: ......
Page 9: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Page 11: ......
Page 12: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...