3-2
888-2685-001
12/24/07
WARNING: Disconnect primary power prior to servicing.
Ranger Commissioning Manual
Section 3 Operation and Adjustments
3.2.1
Main Menu “Hardware” Buttons
Just to the right of the touchscreen, there are 5 hardware
buttons which are part of the front panel overlay.
Located next to each button is a Status LED which
illuminates green under normal, no fault conditions.
These buttons provide quick access to each of the 5
main transmitter groups, namely:
a.
Drive Chain
b.
Power Amp
c.
Output
d.
Power Supply
e.
System
The Status LED next to the button will turn red if there
is a warning or fault condition in that section of the
transmitter. It will be green if the sub-system is normal.
This provides quick access to the required and relevant
diagnostics information, without having to be familiar
with a menu structure.
NOTE:
To differentiate these buttons from the ones which show up on the LCD display,
these will be referred to as “Hardware” buttons in the manual text.
3.3
Graphical User Interface (GUI)
The GUI (“Gooey”) was designed to provide an intuitive interface into the transmitter
control system. Once you know what information is available, finding the information
you want is simply a matter of following the screens to the desired section of the
transmitter. Menu Trees of all available screens is given at the end of this section, see
"3.10 GUI Menu Structures" on page 3-32.
For the most part, all navigation through the GUI screens is done via the touchscreen
and softkeys (software buttons). The exceptions are the 5 hardware buttons mentioned
above. The touchscreen display is also divided into an active display area, which will
change with each screen, and the global areas which are present on all screens.
SYSTEM
Summary of Contents for Ranger Series
Page 4: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing MRH 2...
Page 5: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Page 7: ......
Page 9: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Page 11: ......
Page 12: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...