2-30
888-2685-001
12/24/07
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation Verification &
Ranger Commissioning Manual
2.13.1 Remote Power Metering, J17
Each analog metering output will provide 0 - 4.096Vdc output into a 400 ohm load
(where 3Vdc = Nominal). The connections for J17 are listed in Table 2-3.
Table 2-3 J17, External I/O Board, Remote Power Metering
Connection
Schematic Label
Metered Parameter
J17-1
GND
Ground
J17-2
VOUTA
Total Forward Power (After Filter)
J17-3
VOUTB
Total Reflected Power (After Filter)
J17-4
VOUTC
Forward Power Cabinet #1 (Before Filter)
J17-5
VOUTD
Reflected Power Cabinet #1 (Before Filter)
J17-6
GND
Ground
J17-7
GND
Ground
J17-8
VOUTE
Spare
J17-9
VOUTF
Spare
J17-10
VOUTG
Spare
J17-11
VOUTH
Spare
J17-12
GND
Ground