![Harris Ranger Series Commissioning Manual Download Page 25](http://html2.mh-extra.com/html/harris/ranger-series/ranger-series_commissioning-manual_4040366025.webp)
12/24/07
888-2685-001
1-9
WARNING: Disconnect primary power prior to servicing.
Section 1 Introduction
Ranger Commissioning Manual
Data Input
Input Rate
Mb/s
270
Impedance
Ohms
75
Standard
DVB-
ASI
EN 50083-9
Connector
BNC Female
External Frequency Reference Input
Frequency
Mhz
10 Mhz
Impedance
Ohms
50 Ohms
Level
dBm
Sinusoidal Waveform
0 to +10 dBm
Connector
BNC Female
Performance
Modulation Error Ration
(MER)
dB
Measured at transmitter output
> 33dB
Shoulder Level
dB
Measured at transmitter output before
filter, for 6 MHz channel, F
c
+/- 3 MHz
> 36 dB
Carrier Suppression
dB
> 20
I/Q Imbalance
dB
Residual Sideband Level
> 50
Frequency Tolerance
(without external reference)
Hz
for at least 24 hrs.
1 x 10
-8
Frequency Tolerance (with
external reference)
Hz
for at least 24 hrs.
1 x 10
-9
Pilot Frequency Stability
Hz
With External Reference
Less than +/- 3 Hz
Stability of Output Power
%
Over entire operating temperature range
and indefinite time period
+/-10%, or less
Phase Noise
Frequency Offset Relative to Carrier
Frequency
Phase Noise
100 Hz
-80
1 kHz
-90
10 kHz
-95
100 kHz
-110
1 MHz
-120
> 1 MHz
-120
Spurious Radiation
Conducted Spurious
Radiation
dBc
Measured at transmitter outptut before
filter
< -30
AC Line
Item
Unit
s
Conditions
Value
Summary of Contents for Ranger Series
Page 4: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing MRH 2...
Page 5: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Page 7: ......
Page 9: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Page 11: ......
Page 12: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...