12/24/07
888-2685-001
3-29
WARNING: Disconnect primary power prior to servicing.
Section 3 Operation and Adjustments
Ranger Commissioning Manual
in which information can be changed. The default password is 1895, which will
override any other password and allow access.
The only function button is the Touch Cal or Touchscreen Calibration. This should not
require routine adjustment. The procedure is given next.
Figure 3-24 Control Setup Screen
3.9.3.1.3 Touch Screen Calibration
If the touch screen soft buttons on the GUI are working and seem to be accurate, then
this procedure is not required. If the soft buttons on the touch screen do not seem to
work or can only be activated by pressing outside the button graphic, then a simple
touch screen calibration will have to be done as follows:
STEP 1
Go to the touch screen calibration setup screen by pressing the Touch
Cal button in Figure 3-24. If you are not able to get to the screen, open
the control panel and press and hold the Remote Enable and Disable
buttons at the same time and momentarily reset the main controller. The
Main Controller Reset button is located near the center of the board
(directly behind the GUI). Keep the Enable and Disable buttons pressed
until the display is up and running. After the micro resets, the Main
Controller will prompt the operator to calibrate the touch screen.
STEP 2
Once you see the screen in Figure 3-25, simply touch the X in the first 2
screens. This will get you to the first screen in Figure 3-26.
To Figure 3-22
Summary of Contents for Ranger Series
Page 4: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing MRH 2...
Page 5: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Page 7: ......
Page 9: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Page 11: ......
Page 12: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...