Documentation
The following is a list of documentation that ships with the transmitter. This
documentation should be available for reference during the commissioning process.
The top level Document Package numbers for each transmitter model are shown below:
•
CZ500F & CZ1000F: 988-2687-001
A Document Package includes:
1.
888-2685-001 Commissioning Manual (this technical manual)
2.
888-2497 Ranger
TM
Mobile Series Transmitter Manual
3.
888-2604-001 Apex Exciter using FLO
R
Technology Operating Manual
4.
Drawing Package with a complete set of installation schematics for the
transmitter system
The included CD-ROM contains:
1.
Transmitter control software files of the same revision as loaded into the
transmitter at the factory
2.
ISP (In-System Programming) software application which is used to install
software upgrades into the transmitter controllers.
3.
An Acrobat (pdf) version of the transmitter Technical Manual.
2.2.1
Installation Drawings
It is recommended that you look through the drawing package to familiarize yourself
with the information available. Although drawings are provided for all assemblies in the
transmitter, most of the installation and planning information is given in the following
drawings (in the supplied drawing package):
a.
Transmitter Outline Drawing - 843-5560-071 - Shows physical connection points
for AC and control conduits and RF output. Also gives cabinet dimensions,
required cabinet clearances and a table of basic requirements for both models.
b.
Transmitter Wiring Diagram - 843-5560-001 - Interconnection wiring diagram
for all assemblies inside the transmitter cabinet.
c.
AC Flow Diagram - 843-5560-098 - Shows external AC wiring requirements
along with minimum wire and breaker sizing for each model.
Summary of Contents for Ranger Series
Page 4: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing MRH 2...
Page 5: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Page 7: ......
Page 9: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Page 11: ......
Page 12: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...