Section 4 RF Testing
NOTE:
The operating frequency of 719 MHz is for U.S. operation. Qualcomm may
define other UHF frequencies for international operation
4.2.13.2 Requirement(s)
See Expected Observations column in the following Procedure.
4.2.13.3 Setup and Test Equipment
Table 4-10 Out of Band Emissions Setup
Transmitter
Exciter
Status 1
Active on Exciter A
External GPS Active
Status 2
Active on Exciter B
External GPS Active
Table 4-11 Out of Band Emissions Test Equipment
Spectrum Analyzer
RF Test Cables (with known and measured losses)