PA Module Pallet Replacement
The phase and gain of the individual pallet amplifiers in the PA Module are tightly
controlled in manufacturing allowing field replacement of the individual pallets using a
"PA Pallet Replacement Kit". The PA Modules are designed to cover a specific
frequency range or BAND within the UHF DTV spectrum. The PA Modules for each
band have a different part number and so do the Pallet Replacement Kits. See Table 5-1.
The tools required for the replacement include:
•
Safety glasses
•
Soldering iron
•
Sn63Pb37 solder (Harris Part# 086-0004-054)
•
Alcohol and a piece of cotton cloth
•
Medium size Phillips blade screwdriver
•
Medium size flat blade screwdriver
•
7/64" size Allen wrench with torque indicating mechanism (15 inch pounds)
The Pallet replacement procedure is as described below:
!
WARNING:
THE DIAMOND PA MODULES ARE DESIGNED TO HANDLE VERY HIGH TEMPERA-
TURES AND MAY BE EXTREMELY HOT, UP TO 90
O
F (50
O
C) ABOVE ROOM TEM-
PERATURE. DO NOT TOUCH THE MODULES WITH BARE HANDS AFTER THE
TRANSMITTER HAS BEEN RUNNING, ESPECIALLY IN HIGH AMBIENT TEMPERA-
TURE ENVIRONMENTS. SPECIAL GLOVES HAVE BEEN PROVIDED IN THE REAR
OF THE CONTROL CABINET OR CAN BE OBTAINED FROM HARRIS, PART #099-
0006-483 OR GRAINGER ITEM #4JF36.
STEP 1
Using the protective gloves, remove the PA module from the
Transmitter.
STEP 2
Place the module on the bench with the lid up.
STEP 3
Remove the cover using the Phillips screwdriver to remove all the screws.
Table 5-1 PA Pallet Replacement Kit Part Numbers
Replacement Kit Part #
Channels (Frequency Band)
994-9782-002
42 - 58 (636 - 741MHz)
994-9782-003
59 - 78 (736 - 860MHz)
994-9782-004
14 - 26 (470 - 550MHz)
994-9782-005
27 - 41 (547 - 638MHz)
Summary of Contents for Ranger Series
Page 4: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing MRH 2...
Page 5: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Page 7: ......
Page 9: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Page 11: ......
Page 12: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...