WARNING: Disconnect primary power prior to servicing.
Section 2 Installation Verification &
Ranger Commissioning Manual
d.
RF Flow Diagram - 843-5560-097 - Shows external RF connections and possible
layout for patch panel and dummy load.
e.
Ranger External I/O Connections - 843-5560-105 - Shows connections to the
External I/O board for an RF patch panel or motorized switch.
2.3
Installation Confirmation Checkboxes
Located to the left of each important step in the commissioning procedure is a checkbox
like the one to the left of this paragraph. As each step in the procedure is completed, the
box should be checked. This provides an opportunity for review at the end of the
procedure to insure that no steps were skipped. The primary goal of each step is also
in bold letters, with the rest of the paragraph being support information toward that
goal.
NOTE:
In case of discrepancy between the connections listed in the schematics versus
the information given in this installation section, the wiring information in the
schematics should be considered the most accurate. All connections listed in this
section should be verified with the schematics before initial turn on.
2.4
Transmitter Cabinet Placement
The transmitter cabinet as approximately 3 feet of clearance on each side and in
the back. The front of the transmitter has a clearance of at least 5 feet to allow for
access to the PA and power supply modules.
The transmitter is secured to floor as required by local codes.
The transmitter is level and solid (not rocking).
2.5
Transmitter AC Connection
!
WARNING:
DISABLE AND LOCK OUT STATION PRIMARY POWER BEFORE PRIMARY POWER
CABLES ARE CONNECTED TO THE EQUIPMENT.
NOTE:
The Ranger transmitter is equipped for single phase 208/240Vac at 50/60Hz. If
voltage variations in excess of +/-10% are anticipated, the transmitter power
Summary of Contents for Ranger Series
Page 4: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing MRH 2...
Page 5: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Page 7: ......
Page 9: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Page 11: ......
Page 12: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...