background image

FT-450 CAT O

PERATION

 R

EFERENCE

 B

OOK

CAT

 

(

C

OMPUTER

 A

IDED

 T

RANSCEIVER

)

 

O

PERATION

FT-450

CAT O

PERATION

R

EFERENCE

 B

OOK

Summary of Contents for FT-450 - CAT OPERATION REFERENCE BOOK

Page 1: ...FT 450 CAT OPERATION REFERENCE BOOK CAT COMPUTER AIDED TRANSCEIVER OPERATION FT 450 CAT OPERATION REFERENCE BOOK...

Page 2: ...hnical documenta tion supplied with your computer for correct data connec tion Vertex Standard does not produce CAT System operating software due to the wide variety of personal computers and operatin...

Page 3: ...phabetical characters You may use either lower or upper case characters The commands available for this transceiver are listed in the PC Control Command Tables on the following pages Page 2 Parameters...

Page 4: ...O X X O O O O O O O O O O O O O X O O O O O X O O O X O O O X O O X O X X X X O X X O O O O X O O X O O O O O O X O O O X O O X X O O O X O O O O O O O O O X X X O X X O O O O X O O X O O O O O O X O...

Page 5: ...ver is turned OFF Page 4 BI BI BI BI BI BREAK IN Set 1 2 3 4 5 6 7 8 9 10 B I P1 Read 1 2 3 4 5 6 7 8 9 10 B I Answer 1 2 3 4 5 6 7 8 9 10 B I P1 P1 0 Break in OFF 1 Break in ON BS BS BS BS BS BAND SE...

Page 6: ...DIMMER OFF 1 DIMMER ON CONTROL COMMAND TABLES CH CH CH CH CH CHANNEL UP DOWN Set 1 2 3 4 5 6 7 8 9 10 C H P1 Read 1 2 3 4 5 6 7 8 9 10 Answer 1 2 3 4 5 6 7 8 9 10 P1 0 Memory Channel UP 1 Memory Chan...

Page 7: ...S ED ED ED ED ED ENCODER DOWN Set 1 2 3 4 5 6 7 8 9 10 E D P1 P2 P2 Read 1 2 3 4 5 6 7 8 9 10 Answer 1 2 3 4 5 6 7 8 9 10 P1 0 Fixed P2 01 99 Steps EU EU EU EU EU ENCODER UP Set 1 2 3 4 5 6 7 8 9 10 E...

Page 8: ...63 064 P2 0 OFF 1 ON 0 DISABLE 1 ENABLE 00 OFF 01 hour 12 hour 000 OFF 001 sec 255 sec 0 440 Hz 1 880 Hz 2 1760 Hz 000 FIX 0 100 FIX100 or 101 LNK 50 151 LNK0 201 LNK 50 0 DISABLE 1 ENABLE 0 10 msec 1...

Page 9: ...function as the front panel s A B button 35 A B Set to the same function as the front panel s A B button 36 LOCK Set to the same function as the front panel s LOCK button 37 TUNE Set to the same func...

Page 10: ...B P1 P1 P1 P1 P1 P1 P1 P1 11 12 13 14 15 16 17 18 19 20 Read 1 2 3 4 5 6 7 8 9 10 F B Answer 1 2 3 4 5 6 7 8 9 10 F B P1 P1 P1 P1 P1 P1 P1 P1 11 12 13 14 15 16 17 18 19 20 P1 300000 60000000 Hz Page...

Page 11: ...P1 1 3 Beacon Text Channel Number P2 Message Characters up to 40 characters CONTROL COMMAND TABLES IS IS IS IS IS IF SHIFT Set 1 2 3 4 5 6 7 8 9 10 I S P1 P2 P2 P2 P2 Read 1 2 3 4 5 6 7 8 9 10 I S P1...

Page 12: ...X CLAR ON P6 MODE 1 LSB 2 USB 3 CW 4 FM 5 AM 6 DATA RTTY LSB 7 CW R 8 USER L 9 DATA RTTY USB B FM N C USER U P7 0 VFO 1 Memory P8 0 CTCSS OFF 1 CTCSS ENC DEC 2 CTCSS ENC P9 Tone Number See Table 1 P10...

Page 13: ...er ON CONTROL COMMAND TABLES OI OI OI OI OI OPPOSITE BAND INFORMATION Set 1 2 3 4 5 6 7 8 9 10 Read 1 2 3 4 5 6 7 8 9 10 O I Answer 1 2 3 4 5 6 7 8 9 10 O I P1 P1 P1 P2 P2 P2 P2 P2 11 12 13 14 15 16 1...

Page 14: ...OFF 1 ON R R R R RC C C C C CLAR CLEAR Set 1 2 3 4 5 6 7 8 9 10 R C Read 1 2 3 4 5 6 7 8 9 10 Answer 1 2 3 4 5 6 7 8 9 10 R R R R RG G G G G RF GAIN Set 1 2 3 4 5 6 7 8 9 10 R G P1 P2 P2 P2 Read 1 2...

Page 15: ...SH SH WIDTH Set 1 2 3 4 5 6 7 8 9 10 S H P1 P2 P2 Read 1 2 3 4 5 6 7 8 9 10 S H P1 Answer 1 2 3 4 5 6 7 8 9 10 S H P1 P3 P3 P1 0 Fixed P2 00 10 Narrow 11 21 Normal 22 31 Wide P3 00 Narrow 16 Normal 3...

Page 16: ...TATUS Set 1 2 3 4 5 6 7 8 9 10 Read 1 2 3 4 5 6 7 8 9 10 U L Answer 1 2 3 4 5 6 7 8 9 10 U L P1 P1 0 PLL Lock 1 PLL Unlock CONTROL COMMAND TABLES SV SV SV SV SV SWAP VFO Set 1 2 3 4 5 6 7 8 9 10 S V R...

Page 17: ...5 6 7 8 9 10 VS VS VS VS VS VFO SELECT Set 1 2 3 4 5 6 7 8 9 10 V S P1 Read 1 2 3 4 5 6 7 8 9 10 V S Answer 1 2 3 4 5 6 7 8 9 10 V S P1 P1 0 VFO A 1 VFO B Page 16 VR VR VR VR VR VOICE Set 1 2 3 4 5 6...

Page 18: ...FERENCE BOOK CAT COMPUTER AIDED TRANSCEIVER OPERATION Copyright 2007 VERTEX STANDARD CO LTD All rights reserved No portion of this manual may be reproduced without the permission of VERTEX STANDARD CO...

Reviews: