4. EXC A FAULT: ON = Exciter A is in a Fault condition
5. EXC B FAULT: ON = Exciter B is in a Fault condition
6. SPARE 1:
7. SPARE 2:
8. SPARE 3:
9. SPARE 4:
10.VIS AGC EN: ON = Visual AGC is enabled
11.AUR AGC EN: ON = Aural AGC is enabled
12.UNUSED 010b:
13.PFAIL: ON = Monitor has detected an impending
power failure
14.WDOGFAIL: ON = Monitor Watchdog timer has ex-
pired
15.AD STATUS: ON = Analog to Digital Converter has
conversion failure
16.UNUSED 010f:
6.8
Slave Raw Data Screen Information
The same information is reported for all active slave cabinets on
this screen. Each Column containing a cabinets information is
headed by a cabinet designator:
•
AURA: Aural Cabinet A
•
AURB: Aural Cabinet B
•
VISA: Visual Cabinet A
•
VISB: Visual Cabinet B
•
VISC: Visual Cabinet C
•
VISD: Visual Cabinet D
NOTE
(Not all cabinets present in all configurations.)
The information presented for each cabinet is:
•
AIRF: 1 = Air Fault
•
DORF: 1 = Door Fault
•
PS1F: 1 = Power Supply 1 Fault
•
PS2F: 1 = Power Supply 2 Fault
•
SPAR1: Spare
•
SPAR2: Spare
•
SPAR3: Spare
•
TXD: 1 = Cabinet is OFF
•
MODF: This is a Hexadecimal number with each bit of each
hex digit corresponding to a module slot in the cabinet. The
low order bit of the low order digit refers to slot one, the
next high order bit refers to slot two, and so on up to slot
17. A bit equal to one means that the module in the refer-
enced slot has a fault. See Figure 6-1 and Table 6-1.
•
ID: This is the hexadecimal representation of the cabinet
address as entered in the DIP switches on the Slave Con-
troller. RF1: Peak Detector 1 Output Voltage
•
RF2: Peak Detector 2 Output Voltage
•
RF3: Peak Detector 3 Output Voltage
•
RF4: Peak Detector 4 Output Voltage
•
RF5: Peak Detector 5 Output Voltage
•
RF6: Peak Detector 6 Output Voltage
•
PS1V: Power Supply 1 Voltage Output Monitor voltage
•
PS1A: Power Supply 1 Current Output Monitor voltage
•
PS2V: Power Supply 2 Voltage Output Monitor voltage
•
PS2A: Power Supply 2 Current Output Monitor voltage
Figure 6-1. PA Cabinet
Module Slot Numbers
Section VI - Troubleshooting
888-2365-001
6-3
WARNING: Disconnect primary power prior to servicing.
Summary of Contents for Platinum Series
Page 4: ......
Page 6: ......
Page 8: ...ii 888 2365 001 02 24 97 WARNING Disconnect primary power prior to servicing ...
Page 12: ...This page left blank intentionally ...
Page 22: ...1 10 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 52: ...3 20 888 2365 001 Rev B 1 11 1999 WARNING Disconnect primary power prior to servicing ...
Page 62: ...4 10 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 64: ...4 12 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 66: ...4 14 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 80: ...5 14 888 2365 001 Rev B 1 11 1999 WARNING Disconnect primary power prior to servicing ...