Display Test or Sentry Setup - This screen is displayed when
the SCREEN TEST key is selected on the USER SETUP SELEC-
TION MENU screen. This screen is replaced by a Sentry setup
screen when Sentry is used.
This screen allows the user to test the display panel for any
display problems such as a burned out pixel.
There are 2 active softkeys on this display. They are:
TEST - This key will cause every pixel on the screen to be turned
on. Thus, if any pixels are burned out, they should be easily seen.
*NOTE - After the TEST key has been selected, striking any of
the softkeys will end the test and return the user to the previous
test screen.
EXIT - This key will return the user to the User Setup Menu.
DISPLAY TEST
Press TEST to Begin the Display
Test
Press Any Key to END the Test
TEST
EXIT
Figure 3-15. Display Test
Figure 3-16. System Setpoint Entry
System Setpoint Entry - This screen is displayed when the
POINTS key is selected on the SYSTEM SETUP MENU screen.
This screen allows the user to enter the Visual and Aural forward
powers for the transmitter. These values are used to calculate the
digital display of power and do not increase or decrease the
amount of power output.
New setpoints cannot be entered while the transmitter is on.
There are 5 active softkeys on this screen. They are:
→
- This key advances the cursor through the Visual and Aural
setpoint fields.
- This key increments the value by 1 if you’re in a numeric field
or toggles between PASS and SET.
↓
- This key decrements the value by 1 if you’re in a numeric field
or toggles between PASS and SET.
SET POINTS- This key saves the user entered setpoints in the
database. If the Visual or Aural fields are preceded by PASS,
depressing the SET POINTS command will not change the
system setpoints for the field(s) preceded by PASS. The SET
toggle must be selected and the transmitter must be off for the
system to read the new setpoints when the SET POINTS com-
mand is given.
EXIT - This key will return the user to the System Setup Menu
screen.
Section III - Operation, Controls, and Indicators
Rev. B: 1/11/1999
888-2365-001
3-11
WARNING: Disconnect primary power prior to servicing.
Summary of Contents for Platinum Series
Page 4: ......
Page 6: ......
Page 8: ...ii 888 2365 001 02 24 97 WARNING Disconnect primary power prior to servicing ...
Page 12: ...This page left blank intentionally ...
Page 22: ...1 10 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 52: ...3 20 888 2365 001 Rev B 1 11 1999 WARNING Disconnect primary power prior to servicing ...
Page 62: ...4 10 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 64: ...4 12 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 66: ...4 14 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 80: ...5 14 888 2365 001 Rev B 1 11 1999 WARNING Disconnect primary power prior to servicing ...