1. Visual Specifications
Power Output:
Availible in 1, 2, 5, 10, 15, 20, 30, 45, and 60 kW models, peak sync
power. (Measured at output of optional diplexer.)
RF Load Impedance:
50 Ohms
Output Connector
1-10 kW:
1
5
/
8" EIA
15-60 kW LS:
3
1
/
8" EIA
15-30 kW HS:
3
1
/
8" EIA
45-60 kW HS:
4
1
/
16" EIA
Systems:
M/NTSC, B/PAL, B/SECAM
Frequency Range
LS (low band):
System M: 54-88 MHz
System B: 47-68 MHz
HS (high band):
System M: 174-216 MHz
System B: 174-230 MHz
Carrier Frequency Stability
Standard: +250 Hz maximum variation per 30 days. After 60 days initial
aging.
Optional: +2 Hz with precise frequency control.
Video Input
Impedance:
75 Ohms, return loss 32 dB min. to 5.5 MHz.
Level:
0.7 - 2.0 Volts, peak to peak
Visual Modulation Capability:
0%. (Measured using synchronous detector.)
Visual Sideband Response
(Measured at output of color notch filter, with transmitter operating into
a resistive load, VSWR = 1.05:1 or better.)
NTSC/M
-1.25 to -4.25 MHz:
-23 dB or better
-3.58 MHz:
-42 dB or better
-0.75 to +4.10 MHz:
+0.5 dB
+4.18 MHz:
+0.5 to -1.0 dB
+4.50 MHz:
-30 dB or better
+4.75 to + 7.75 MHz:
-40 dB or better
B/PAL and B/SECAM
-1.25 MHz and lower:
-20 dB or better
-4.43 MHz:
-30 dB or better
-0.75 to +5.0 MHz:
+0.5 dB
+5.5 MHz:
-30 dB or better
Frequency Response vs. Brightness:
+0.75 dB or better. Measured using a 20% p.p. swept video modulation
on a pedestal at 10%, 50% and 90% APL (all percentages relative to a
blanking to white excursion).
Differential Gain:
3% or better. Measured with a 5-step staircase signal from 75% to
12.5% peak-sync power, with 12.5% p.p. chroma subcarrier modulation.
Differential Gain vs. APL:
+5% or better. APL defined as the pedestal level over four lines at 10%,
50%, and 90% of maximum white level, with a standard 5-step chromi-
nance-modulated staircase inserted every fifth line.
Differential Phase:
+1° or better. Measured with the same 5-step staircase signal as in Dif-
ferential Gain.
Incidental Carrier Phase Modulation (ICPM):
+1.5° or better. Carrier phase variation from reference white to sync tip,
referenced to 0 at blanking, and measured with the same 5-step stair-
case signal as in Differential Gain.
Luminance Non-linearity:
1.0 dB or better. Measured with a 5-step staircase signal, Test Signal #3
CCIR Rec. 421-3.
Table 1-1. Specifications
Section I - Introduction
888-2365-001
1-7
WARNING: Disconnect primary power prior to servicing.
Summary of Contents for Platinum Series
Page 4: ......
Page 6: ......
Page 8: ...ii 888 2365 001 02 24 97 WARNING Disconnect primary power prior to servicing ...
Page 12: ...This page left blank intentionally ...
Page 22: ...1 10 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 52: ...3 20 888 2365 001 Rev B 1 11 1999 WARNING Disconnect primary power prior to servicing ...
Page 62: ...4 10 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 64: ...4 12 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 66: ...4 14 888 2365 001 WARNING Disconnect primary power prior to servicing ...