used most often for the remote control system failsafe interlock,
diplexer air switch, etc.
VSWR FOLDBACK ACTIVE: Indicates elevated VSWR has
caused the transmitter to reduce its output power by some
amount. Foldback allows uninterrupted operation if the VSWR
slowly increases. If the VSWR exceeds a certain threshold, the
foldback will begin to operate. As the VSWR increases, forward
power will be reduced to maintain a constant level of reflected
power. If the VSWR decreases, power output will increase to-
ward the original setting. Foldback will end and the lamp will be
extinguished if the VSWR drops below the threshold.
While VSWR foldback is active, VSWR fault detection is inhib-
ited. However, protection from high VSWR is then provided by
the individual module VSWR fault circuits.
MODULE FAULT: Indicates one or more of the cabinet RF
amplifier modules is reporting a fault.
MONITOR FAULT: Indicates the monitor has failed and all
calculated readings may be incorrect.
PHASE LOSS: Indicates the control cabinet phase loss detector
senses loss of one of the three phase power lines, voltage below
threshold, or reversal of the phase sequencing. (If all cabinet
indications are dark the phase feeding the logic power supplies
is probably lost.)
AURAL DRIVE CHAIN FAULT (optional): Indicates an aural
driver has failed in the parallel aural driver chain.
EXTERNAL INTERLOCK: When open, the External Interlock
will prevent the transmitter from turning on. The circuit must be
closed through the external interlock device for normal opera-
tion. The External interlock will turn the transmitter off if it is
opened. It can be programmed either to require a manual ON
command to restart the transmitter, or to restart the transmitter
automatically (check Main Controller) after the interlock is
re-closed.
3.1.4
User Display Panel
This section contains instructions for the user display panel.
Refer to Figures 3-2 and 3-3.
NOTE
Screen Blanking Option - Refer to Figure 5-7 for information on
setting Screen Blanking on or off. If screen blanking is enabled,
the screen will blank after 1 hour of inactivity on the display
function keys. Any display function keypress after screen blanking
will redisplay last screen. While screen is blanked, alarms that
are normally shown on the screen will not be displayed on the
screen until the screen is unblanked.
Figure 3-2. Monitor Screen Flow
3-2
888-2365-001
Rev. B: 1/11/1999
WARNING: Disconnect primary power prior to servicing.
Summary of Contents for Platinum Series
Page 4: ......
Page 6: ......
Page 8: ...ii 888 2365 001 02 24 97 WARNING Disconnect primary power prior to servicing ...
Page 12: ...This page left blank intentionally ...
Page 22: ...1 10 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 52: ...3 20 888 2365 001 Rev B 1 11 1999 WARNING Disconnect primary power prior to servicing ...
Page 62: ...4 10 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 64: ...4 12 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 66: ...4 14 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 80: ...5 14 888 2365 001 Rev B 1 11 1999 WARNING Disconnect primary power prior to servicing ...