tion by momentarily switching the fan breaker off while observ-
ing the air loss LED.
5.4
Cleaning
Use a vacuum cleaner as required to clean the cabinets. Be aware
of static discharge problems with the use of high velocity air in
dry climates when cleaning any circuit-board with static sensitive
components. A variety of static-safe vacuum equipment is avail-
able at most computer supply dealers.
A soft natural bristled paint brush with metal binding and wood
handle can be used to dislodge dust with minimum static genera-
tion. Hold the metal binding and touch a grounded surface to
discharge any difference in potential before working on the
board. Do not use nylon brushes with plastic handles.
Printed circuit board edge connectors may be cleaned using a
commercial cleaner such as Cramolin. Apply a small amount of
the cleaner to the contacts, then remove it with a clean, lint-free
cloth. Do not use a pencil eraser to clean contacts, as gold or
silver contact plating will be removed.
To clean motherboard sockets, wrap cloth around a small plastic
or metal card slightly thinner than the circuit boards. Apply a
small amount of the cleaner, and insert the cloth-covered card
into the connector. Reposition the cloth to a dry area to remove
the cleaner.
Inspect the RF amplifier module fins for accumulated dirt that
may have gone past the air filters. Remove using a brush and
vacuum.
Do not spray any liquids that may seep into the circuit board area.
Outside panel surfaces may be cleaned with a damp cloth using
water or mild household cleaners.
5.5
Fan Motor Currents
To measure fan motor current, use a remote clamp-on current
probe such as Fluke style B or C. Route its leads out through top
of cabinet. The gasket will compress around the leads when door
is shut.
Measure the cabinet intake blower currents. If an exhaust blower
is used, measure its currents as well.
Note the AC line voltage readings at this time as well, and record
the current and voltage data for future reference in Table 5-2.
As the motor bearings wear, the motor current may increase. A
periodic check will alert you to this change, indicating that
service is needed and preventing an untimely failure.
5.6
Motor Lubrication
The original blower has sealed, permanently lubricated bearings.
No routine service is required. In the event an alternate supplier
was used for motor replacement, check for grease fittings on the
motors. If found, lubricate motor annually using any of the
following:
•
Shell “Dolium R”
•
Chevron “SRI No 2”
•
Texaco “Premium RB”
Excess grease can cause premature bearing failure. Do not allow
the grease to be contaminated. Turn the motor off and allow it to
stop rotating before greasing the bearings. Do not mix petroleum
and silicone grease.
5.7
Check Connections
WARNING
DISCONNECT ALL POWER TO TRANSMITTER BEFORE PER-
FORMING THE FOLLOWING STEP.
All wiring should be periodically checked for tight connections.
This is most important in the high-current circuits (cabinet AC
feed, AC breaker to DC power supplies, power supply to DC bus,
DC bus to module connectors, etc.). Also check wires for lead
LINE VOLTAGES
A-B
B-C
A-C
CURRENTS
AURAL PA FAN MOTOR
AURAL PA FAN MOTOR
A
A
B
B
C
C
VISUAL PA A FAN MO-
TOR
VISUAL PA C FAN
MOTOR
A
A
B
B
C
C
VISUAL PA B FAN MO-
TOR
VISUAL PA D FAN
MOTOR
A
B
C
INPUT BLOWER MOTOR
EXHAUST BLOWER
MOTOR
A
A
B
B
C
C
Table 5-2. Line Voltages and Currents
Section V - Maintenace
Rev. B: 1/11/1999
888-2365-001
5-3
WARNING: Disconnect primary power prior to servicing.
Summary of Contents for Platinum Series
Page 4: ......
Page 6: ......
Page 8: ...ii 888 2365 001 02 24 97 WARNING Disconnect primary power prior to servicing ...
Page 12: ...This page left blank intentionally ...
Page 22: ...1 10 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 52: ...3 20 888 2365 001 Rev B 1 11 1999 WARNING Disconnect primary power prior to servicing ...
Page 62: ...4 10 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 64: ...4 12 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 66: ...4 14 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 80: ...5 14 888 2365 001 Rev B 1 11 1999 WARNING Disconnect primary power prior to servicing ...