LINE VOLTAGE INFORMATION
ALARM
Line Voltages:
Phase A-B
208 V
Phase B-C
Phase A-C
208 V
208 V
VISUAL
AURAL
SUPPLY
EXIT
Figure 3-9. Line Voltage Information Screen
Line Voltage Information screen - This screen is displayed
when the LINE key is selected while viewing either power supply
information screen or a visual or aural information screen. This
screen displays each phase voltage of the three phases in the
system. These voltages are sampled at the control cabinet.
There are 4 active softkeys on this screen. They are:
VISUAL - This key will display the Visual information screen 1.
AURAL - This key displays the aural information in the system.
SUPPLY - This key will display the Power Supply information
of the transmitter system.
EXIT - This key will return the user to the Bargraph Meter screen.
Figure 3-10. User Setup Selection Menu
User Setup Selection Menu screen
This screen is called up when SETUP key is depressed while
viewing the bargraph meter screen (default).
This screen is used to select 1 of the 4 user available options.
There are 5 active softkeys on this screen. They are:
TIME - This key selects the Time and Date entry screen.
USER - This key selects the User Display Edit screen
TEST - This key selects the display panel test screen or Sentry
Setup.
SETPOINT - This key selects the Power Setpoints Edit System.
EXIT - This key will return the user to the Bargraph Meter screen.
3-8
888-2365-001
Rev. B: 1/11/1999
WARNING: Disconnect primary power prior to servicing.
Summary of Contents for Platinum Series
Page 4: ......
Page 6: ......
Page 8: ...ii 888 2365 001 02 24 97 WARNING Disconnect primary power prior to servicing ...
Page 12: ...This page left blank intentionally ...
Page 22: ...1 10 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 52: ...3 20 888 2365 001 Rev B 1 11 1999 WARNING Disconnect primary power prior to servicing ...
Page 62: ...4 10 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 64: ...4 12 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 66: ...4 14 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 80: ...5 14 888 2365 001 Rev B 1 11 1999 WARNING Disconnect primary power prior to servicing ...