3.3
Phase and Gain Module
Figure 3-21. Phase and Gain Module
1. Place RUN/SET switch in SET position.
2. Adjust INIT control (COARSE PHASE) for minimum reject load power.
3. Adjust A or B GAIN as necessary for minimum reject load power.
4. Place RUN/SET switch in RUN position and /- PHASE for minimum reject load power.
Table 3-3. Phase and Gain Module Set-Up
Section III - Operation, Controls, and Indicators
Rev. B: 1/11/1999
888-2365-001
3-15
WARNING: Disconnect primary power prior to servicing.