Visual Power
Visual VSWR
Aural Power
Aural VSWR
METER
SETUP
DATA
100 %
1.10:1
100 %
1.10:1
ALARM
Date
Time
0
l
50
80
l
100
l
120
0
l
50
80
l
100
l
120
1.0
l
1.5
l
2.0
1.0
l
1.5
l
2.0
Figure 3-4. Bargraph Meter Screen
Bargraph Meter Screen
This screen is the initial screen displayed on power-up and will
likely be the screen that is displayed the most. This screen
displays 4 meter values in both graphic and digital forms. The
default values shown are Visual forward power, Visual VSWR,
Aural forward power, and Aural VSWR. This is the default
screen from which all other screens are accessed. These 4 meters
value may be selected by the user on the USER DISPLAY
SETUP screen.
This screen has 4 active softkeys; METER, SETUP, DATA, and
ALARM. The HELP key is always available on each screen.
Generally visual/aural power and VSWR will be selected, but
other signals may be chosen for trouble shooting.
The ALARM key has a special function. When the ALARM
label is flashing this indicates that there is an active alarm in the
alarms queue. If the ALARM is on solid, it means that there are
alarms in the queue that are inactive, they occurred but the
condition has gone away. If there are no alarms in the queue, the
ALARM will be blank and no access will be allowed into the
Alarms page.
The METER key will take the user to the multi-meter informa-
tion in the system. The first information displayed by invoking
the METER key are the Visual data in the system. From this
screen the rest of the metering information of the system may
be accessed.
The SETUP key will take the user to the user setup menu. From
this screen the user may select from the 4 user definable items;
Time & Date entry, user informaiton edit, screen test, and the
power setpoints edit.
The DATA key will call up the raw data used by the system
monitor. There are two pages. The first is the MAIN raw data
screen and from it you may access the SLAVE raw data screen.
Use of the data pages is a troubleshooting function and is not
normally required by the operator. Some monitor system func-
tions are not active while viewing the data pages.
Section III - Operation, Controls, and Indicators
Rev. B: 1/11/1999
888-2365-001
3-5
WARNING: Disconnect primary power prior to servicing.
Summary of Contents for Platinum Series
Page 4: ......
Page 6: ......
Page 8: ...ii 888 2365 001 02 24 97 WARNING Disconnect primary power prior to servicing ...
Page 12: ...This page left blank intentionally ...
Page 22: ...1 10 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 52: ...3 20 888 2365 001 Rev B 1 11 1999 WARNING Disconnect primary power prior to servicing ...
Page 62: ...4 10 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 64: ...4 12 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 66: ...4 14 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Page 80: ...5 14 888 2365 001 Rev B 1 11 1999 WARNING Disconnect primary power prior to servicing ...