![Harris BMXDIGITAL 99-1200-0 Operation & Technical Manual Download Page 74](http://html1.mh-extra.com/html/harris/bmxdigital-99-1200-0/bmxdigital-99-1200-0_operation-and-technical-manual_4020803074.webp)
Revision C • 1/04
H
A
R
R
I
S
C
O
R
P
O
R
A T
I
O
N
2-62
2 Installation
digital
P
P
P
P
PIN #
IN #
IN #
IN #
IN # SIGNAL
SIGNAL
SIGNAL
SIGNAL
SIGNAL
FUNCTION
FUNCTION
FUNCTION
FUNCTION
FUNCTION
1
LOGIC GROUND
Console logic ground.
2
LOGIC GROUND
Console logic ground.
3
LOGIC GROUND
Console logic ground.
4
STOP COMMAND PULSE
Stop command output. N/O relay contact.
5
START COMMAND PULSE
Start command output. N/O relay contact.
6
LOGIC 5 VDC
5 volt source.
7
ON INPUT (-)
Remote On switch input (active low).
8
OFF INPUT (-)
Remote Off switch input (active low).
9
COUGH INPUT (-)
Remote Cough switch input (active low).
10
LOGIC 5 VDC
5 volt source.
11
LOGIC 5 VDC
5 volt source.
12
LOGIC 5 VDC
5 volt source.
13
COMMANDS COMMON
Start/Stop Pulse, Start Sustained common. C relay contact.
14
TALLIES COMMON
Tally relays common connection. C relay contact.
15
CUE TALLY
Cue tally output. N/O relay contact.
16
OFF TALLY
Off tally output. N/O relay contact.
17
ON TALLY
On tally output. N/O relay contact.
18
ACTIVATE LOGIC INS (+)
+VDC to enable external inputs On, Off, Cough, Talkback.
19
RESET (-)
Remote Audio Off input (active low).
20
REMOTE CUE (-)
Activates the Cue function (active low).
21
READY (-)
Remote Ready input (active low).
22
RESET (+)
+VDC to enable Audio Reset function (audio off control).
23
START SUSTAINED
Start sustained command output. N/O relay contact.
24
READY (+)
+VDC to enable the Ready function (Off lamp control) .
Notes:
+VDC is b5 and +40 VDC.
Output relays can switch voltages up to +60 VDC
Bold
indicates connections used in this example.
UNIVERSAL INPUT MODULE MAIN LOGIC CONNECTOR SIGNAL TABLE
(wire insertion
end view)
Complex Logic Connection Example
This example shows setting up a Universal Input module (A input, analog) to interface with a
remote logic device, such as an ENCO DADpro. For more information on logic connections and DIP
switch settings for the Universal Input module, see pages 2-18 through 2-23.
UNIVERSAL INPUT MODULE SWITCH SETTINGS
#
Switch Name
Setting
1
Signal Source
OFF
2
CR Mute
OFF
3
Studio 1 Mute
OFF
4
Studio 2 Mute
OFF
5
External Site Mute
OFF
6
Local ON Cough
OFF
7
Timer Reset
ON
8
Ready Lamp Status
OFF
DS1
#
Switch Name
Setting
1
Fader Start
OFF
2
Start Pulse
OFF
3
Start/Stop Pulse
OFF
4
Bypass SRC Converter
OFF
5
Spare Switch
OFF
6
Spare Switch
OFF
7
Input Level Set
OFF
8
Input Level Set
OFF
DS2
Note:
ON settings are to the operator’s left. OFF settings are to the operator’s right.
12
11
10
9
8
7
6
5
4
3
2
1
24
23
22
21
20
19
18
17
16
15
14
13