2-54
2 Installation
digital
QUICK GUIDE TO THE OUTPUT 2 MODULE
Fourteen connectors come standard on the Output 2 module: seven 6-pin analog audio output con-
nectors and seven 3-pin digital audio output connectors. The connectors are hidden by the meter panel
in normal operation.
ANALOG OUTPUTS
PGM-1, PGM-2 —
PGM-1, PGM-2 —
PGM-1, PGM-2 —
PGM-1, PGM-2 —
PGM-1, PGM-2 —
The 6-pin analog outputs for the Program 1 and
Program 2 buses are wired using the standard pinout sequence shown
below. The MAIN and AUX connectors are isolated outputs that carry the
same signals (the Program 1 bus or the Program 2 bus).
UTL-1, UTL-2 —
UTL-1, UTL-2 —
UTL-1, UTL-2 —
UTL-1, UTL-2 —
UTL-1, UTL-2 —
The 6-pin analog outputs for the Utility 1 and 2 buses
are wired using the standard pinout sequence shown below.
SEND-1 —
SEND-1 —
SEND-1 —
SEND-1 —
SEND-1 —
The 6-pin analog output for the Send 1 bus is wired using the
standard pinout sequence shown below.
DIGITAL OUTPUTS
PGM-1, PGM-2 —
PGM-1, PGM-2 —
PGM-1, PGM-2 —
PGM-1, PGM-2 —
PGM-1, PGM-2 —
The 3-pin AES-3 (AES/EBU-compatible) digital
outputs of the Program 1 and Program 2 buses. The MAIN and AUX
connectors are isolated outputs that carry the same signals (the Program 1
bus or the Program 2 bus), but the AUX output can be set to either 48 kHz
or 44.1 kHz sampling by SAMPLE RATE DIP switches. The MAIN output is
fixed at 48 kHz sampling.
UTL-1, UTL-2 —
UTL-1, UTL-2 —
UTL-1, UTL-2 —
UTL-1, UTL-2 —
UTL-1, UTL-2 —
The 3-pin AES-3 (AES/EBU-compatible) digital outputs
of the Utility 1 and Utility 2 buses. The outputs can be set to either 48 kHz or
44.1 kHz sampling by SAMPLE RATE DIP switches.
SEND-1 —
SEND-1 —
SEND-1 —
SEND-1 —
SEND-1 —
The 3-pin AES-3 (AES/EBU-compatible) digital outputs the
Send 1 bus. The output can be set to either 48 kHz or 44.1 kHz sampling by
a SAMPLE RATE DIP switch.
Analog Outputs
Right High (+)
Right Low (-)
Shield
Left High (+)
Left Low (-)
Shield
3
2
1
6
5
4
(wire insertion end view)
Digital Outputs
High (+)
Low (-)
Shield
(wire insertion end view)
3
2
1