![Harris BMXDIGITAL 99-1200-0 Operation & Technical Manual Download Page 58](http://html1.mh-extra.com/html/harris/bmxdigital-99-1200-0/bmxdigital-99-1200-0_operation-and-technical-manual_4020803058.webp)
Revision C • 1/04
H
A
R
R
I
S
C
O
R
P
O
R
A T
I
O
N
2-46
2 Installation
digital
STUDIO MODULE — EXTERNAL AUDIO & LOGIC, WITH SETUP DIP SWITCH 7 OFF
The 16-pin EXTERNAL connector has the
external site’s talkback logic inputs and com-
mand output as well as the External site’s talk-
back audio in and out.
Both audio in and out are ba4 dBu
analog connections. A mic preamp is required
for the External site’s talkback microphone.
One of the Mic Preamp module’s ten mic
preamps could be used for this function.
A Talk to External Tally (that pulls low) is
available to command a lamp or LED indica-
tor that talk to external is being received.
Pins 4 and 5 change their functions depend-
ing upon whether SETUP DIP switch 7 is set
On or Off. When DIP switch 7 is off (the de-
fault setting, as shown on this page), pins 4
and 5 are the logic inputs Talk to Studio 1 and
Talk to Studio 1 Host.
When DIP switch 7 is on (see pages 2-50
and 2-51), pins 4 and 5 become the command
outputs External Mute and External Dim.
Studio Module, EXTERNAL (DIP switch 7 Off ) — Simplified Logic Diagram
EXTERNAL Connector, with DIP Switch 7 set Off
Logic 5 VDC
Logic 5 VDC
Talk to External Tally
Talk to Studio 1 Host (-)
Talk to Studio 1 (-)
Talkback Audio Out (-)
Talkback Audio In Shield
Talkback Audio In (-)
Logic Ground
Activate Logic Inputs (+)
Talk to Control Room (-)
Talk to Studio 2 Host (-)
Talk to Studio 2 (-)
Talkback Audio Out (+)
Talkback Audio Out Shield
Talkback Audio In (+)
8
7
6
5
4
3
2
1
16
15
14
13
12
11
10
9
(wire insertion end view)
Talkback Audio Pins
Audio Out (pins 3,10,11)
Audio In (pins 1, 2, 9)
15
13
12
Inter
nal Logic
Talk to Studio 2 (-)
Talk to Studio 2 Host (-)
Activate Logic Inputs (+)
Logic Ground
16
Logic 5VDC
Logic 5VDC
6 Talk To External Tally
7
8
5
4
Talk to Studio 1 (-)
Talk to Studio 1 Host (-)
14
Talk to Control Room (-)
Notes:
Opto-Isolated inputs are current limited and work
with +5 to +40 VDC logic.
Opto-Isolated outputs can sink up to 60 volts or
350 mA max. current flow.