![Harris BMXDIGITAL 99-1200-0 Operation & Technical Manual Download Page 42](http://html1.mh-extra.com/html/harris/bmxdigital-99-1200-0/bmxdigital-99-1200-0_operation-and-technical-manual_4020803042.webp)
Revision C • 1/04
H
A
R
R
I
S
C
O
R
P
O
R
A T
I
O
N
2-30
2 Installation
digital
REMOTE LINE SELECTOR MODULE — LOGIC I/O
The 24-pin LOGIC I/O connector allows the RLS
module to control, or to be controlled by, the device
connected to the module. A device can connect di-
rectly to the module, but more commonly input se-
lection would be done through a switcher. Two types
of switchers are supported: VistaMax (or other rout-
ers) and the PRE99-947 External Remote Line Se-
lector (Ext. RLS).
The source type (switcher or direct) and the
switcher type (VistaMax or Ext. RLS) are set via
the module’s SETUP DIP switches (see page 2-29).
When the module connects to an Ext. RLS, sev-
eral logic connections (pins 15, 16, 17 and 23) be-
come RLS address outputs. This change occurs only
when DS2-4 is set ON and DS2-5 is set to OFF.
When a VistaMax or other router is used (DS2-5 is
set ON), these pins do not change function since
addressing is done through the Session module.
LOGIC I/O Connector
Logic 5 VDC
Logic 5 VDC
Logic 5 VDC
no connection
Off (-)
On (-)
Logic 5 VDC
Start Command Pulse
Stop Command Pulse
Logic Ground
Logic Ground
Logic Ground
Ready (+)
Start Command Sustained / RLS-3
Reset (+)
Ready (-)
no connection
Reset (-)
Activate Logic Inputs (+)
On Tally / RLS-2
Off Tally / RLS-1
Logic Active Tally / RLS-0
Tallies / RLS-0, RLS-1, RLS-2 Common
Commands / RLS-3 Common
12
11
10
9
8
7
6
5
4
3
2
1
24
23
22
21
20
19
18
17
16
15
14
13
(wire insertion end view)
Remote Line Selector (RLS) Module, LOGIC I/O — Simplified Logic Diagram
18
19
21
7
8
24
22
13
15
23
4 Stop Command Pulse
Direct / Router: Start Command Sustained
Ext. RLS Switcher: RLS-3
Commands Common / RLS-3 Common
Direct / Router: Logic Active Tally
Ext. RLS Switcher: RLS-0
Logic Ground
Logic Ground
Logic Ground
Tallies Common / RLS-0, -1, -2 Common
Direct / Router: On Tally
Ext. RLS Switcher: RLS-2
17
16
14
1
2
3
12
11
10
6
Inter
nal Logic
5 Start Command Pulse
Direct / Router: Off Tally
Ext. RLS Switcher: RLS-1
Logic 5VDC
Logic 5VDC
Logic 5VDC
Logic 5VDC
On (-)
Off (-)
Ready (-)
Reset (-)
Activate Logic Inputs (+)
Reset (+)
Ready (+)
Notes:
Opto-Isolated inputs are current limited and work with +5 to +40 VDC logic.
Opto-Isolated outputs can sink up to 60 volts or 350 mA max. current flow.