2-40
888-2523-001
7/26/05
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation / Initial Turn-On
ATLAS Analogue
2.15 Remote Status Outputs, J15 & J16
All of the remote status outputs are open collector and will sink 100mA at up to +24Vdc
to provide an indication status is active. The pull up supply voltage for the status
indications can be supplied via J15 & J16 or can be supplied by an external voltage
source. The status output connections are listed in Table 2-12.
Table 2-12 J15 & J16, External I/O Board, Remote Status Outputs
Connector
and pin #
Schematic Label
Status Output
Status Type and Polarity
J16-1
GNDB
Isolated Ground
J16-2
+5VDC ISOLATED
Output: Install jumper to J16-11
to use this internal supply for
status pull ups. Otherwise an
external supply will have to be
connected to J16-11.
J16-3
/OUTPUT 1
OFF/ON Status
L=ON
H=OFF
J16-4
/OUTPUT 2
Drive A/B Status
L= Drive A
H= Drive B
J16-5
/OUTPUT 3
Drive AUTO/MANUAL Status
L= Auto
H= Manual
J16-6
/OUTPUT 4
Pump A/B Status
L= Pump A
H= Pump B
J16-7
/OUTPUT 5
Pump A/B AUTO/MANUAL
Status
L= Auto
H= Manual
J16-8
/OUTPUT 6
Remote Enabled
L= Enabled
H= Disabled
J16-9
/OUTPUT 7
External Interlock Open
L= Interlock OPEN
H= Interlock CLOSED
J16-10
/OUTPUT 8
RF Muted
L= RF Mute ON
H= RF Mute OFF
J16-11
+VDC EXT SUPPLY
Input For External Pull Up
Supply Voltage
J16-12
GNDB
Isolated Ground
J15-1
GNDB
Isolated Ground
Summary of Contents for ATLAS ANALOGUE
Page 4: ...iv 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Page 6: ...vi 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Page 8: ...viii 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Page 10: ...x 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Page 14: ...Table of Contents continued 4...