7/26/05
888-2523-001
2-21
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation / Initial Turn-On
ATLAS Analogue
NOTE:
Table 2-7 provides typical reference values only. Check the pump and fan motor
labels to verify the actual FLC ratings for each setting.
Energize the AC mains supply to the Cooling Control Panel.
Turn ON the AC mains disconnect switch on the Cooling Control Panel. This will
supply AC power to the Pump Module and the Heat Exchanger.
Press the Local button on the Cooling Control Panel (LED should illuminate).
There are two modes of operation of the cooling pumps: Local and Remote. The
selection is made on the Cooling Control Panel. In the Remote mode, the pumps will
not start until they are commanded to do so by the transmitter. The local mode can be
used for start-up, testing and troubleshooting.
Select Pump A on Cooling Control Panel (LED should illuminate).
Fill the pump module tank with water. See section B.1 Coolant and Water
Recommendations in Appendix B for more information.
Table 2-7 Pump and Fan Trip Settings - Typical
Atlas Transmitter
208/220/240 VAC Mains
380/400/415 VAC Mains
DVA2500 or DVA5000
Pump Module (for each)
8.0A
4.3A
Fan (for each)
1.4A
0.8A
DVA10000
Pump Module (for each)
11.6A
6.4A
Fan (for each)
1.6A
0.9A
DVA20000
Pump Module (for each)
23.1A
12.0A
Fan (for each)
12.1A
8.8A
DVA 30000
Pump Module (for each)
36.0A
18.2A
Fan (for each)
12.1A
8.8A
Summary of Contents for ATLAS ANALOGUE
Page 4: ...iv 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Page 6: ...vi 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Page 8: ...viii 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Page 10: ...x 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Page 14: ...Table of Contents continued 4...