2-30
888-2523-001
7/26/05
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation / Initial Turn-On
ATLAS Analogue
2.13 Initial Turn-On
Read and understand the entire initial turn-on procedure before starting. Detailed use of
all GUI screens is given in Section 3 Operation.
Shut off the front panel breaker.
Apply 3 phase primary power to the transmitter. Be ready to quickly disconnect the
power if necessary.
Engage the primary AC breaker switch, CB9 on the front breaker panel of each
transmitter cabinet.
Turn on the AC mains switch on the rear of the exciter(s). This should apply power
to the exciter(s). If the optional exciter UPS (Un-interruptible Power Supply) is
installed it should be active at this time.
Turn on the LVPS1 and LVPS2 (Low Voltage Power Supply) circuit breakers,
CB11 and CB12. This will activate LVPS1 and LVPS2 and power up the transmitter
control system. The GUI display should show the Home (default) screen shown in
Figure 2-4. Try using the touchscreen buttons on the right side of the GUI display (not
the hardware buttons to the right of the GUI). If they do not seem to be working or only
work when pressed outside the button graphic, then go to "5.6.5 Touch Screen
Calibration" on page 5-19 before continuing. If the buttons are working then proceed
on to the next step.
Figure 2-4 Home Page
Summary of Contents for ATLAS ANALOGUE
Page 4: ...iv 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Page 6: ...vi 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Page 8: ...viii 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Page 10: ...x 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Page 14: ...Table of Contents continued 4...