WARNING: Disconnect primary power prior to servicing.
Section 3 Operation
ATLAS Analogue
Figure 3-28 Cooling Service Screen
3.9.3
System Log
This screen is accessed by pressing the System Log button on the System screen in
Figure 3-23 on page 3-24. It is a complete listing of all transmitter and system faults in
the order in which they occurred. It can hold up to 99 faults and then becomes a FIFO
(First IN - First Out) memory buffer, with the latest fault entry on top. Active Faults
will be highlighted and cannot be reset. All other faults will be cleared when the RESET
button is pressed. Use the NEXT and PREVious buttons to view the entire list.
A complete listing of all faults which can show up in this log, along with a brief
explanation of each fault, is given in the following tables in Section 6, Diagnostics.
•
Table 6-1, “Atlas Transmitter Fault List,” on page 6-4
•
Table 6-2, “Atlas PA Module Fault List,” on page 6-9.
These tables are a quick reference list and in most cases is all that is required for
advanced user to diagnose the problem. However, detailed information on each of these
faults is also given in context with the fault page where it originated, also in Section 6.
To Figure 3-25
Summary of Contents for ATLAS ANALOGUE
Page 4: ...iv 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Page 6: ...vi 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Page 8: ...viii 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Page 10: ...x 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Page 14: ...Table of Contents continued 4...