7/26/05
888-2523-001
2-17
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation / Initial Turn-On
ATLAS Analogue
terminal block clamp in order to insert the cable. Release the clamp to secure the cable
firmly in place.
Connect the safety ground wire to TB5. Connect AC safety ground to smaller
terminal located nearest to sidewall.
Figure 2-2 AC Connections to Terminal Block TB5
Verify that the Primary AC line voltage is correct for the installed MOV board.
Measure the primary AC line voltage from phase to phase and write it in the blank
below. The transmitter was setup in the factory with a 208/220/240 or 380/400/415Vac
Delta or WYE 3 phase configured MOV board. Make sure that the transmitter is setup
for the same power configuration used at the site by checking the factory test data sheet.
VAC
NOTE:
There must be less than a 10% imbalance between the phases to allow the trans-
mitter to operate, however the phase imbalance must be 5% or less to meet trans-
mitter specifications.
AC Primary
Connections
AC Safety Ground Connection