
Preassembly
(OWMANYFOILSANDCONNECTORSs3TRINGINGCONNECTORS
June 1999
Unit 00AL
17
Pin-to-Pin Headstay Length (See Pg 8)
Longueur axe à axe de l’étai (Voir Pg 8)
Bolzen-Bolzen-Mass Anzahl des Vorstages (s.S. 8)
Lunghezza perno-a-perno dello strallo (vedi p. 8)
Number 6" (152 mm) Connectors
Nombre de connecteurs de 152 mm utilisée
Anzahl benötigter Verbinder von 152mm
Numero di estrusi da 152 mm usati
17'6" to 18'2" (5.334 m to 5.537 m)
2
18'3" to 25'2" (5.563 m to 7.671 m)
3
25'3" to 32'2" (7.696 m to 9.804 m)
4
32'3" to 35' (9.830 m to 10.668 m)
5*
Number 7' (2.13 m) Foils Used
Nombre de profils de 2.13 m utilisée
Anzahl benötigter Profile von 2.13m
Numero di estrusi da 2.13 m usati
17'6" to 24'6" (5.334 m to 7.468 m)
2
24'7" to 31'6" (7.493 m to 9.601 m)
3
31'7" to 35' (9.627 m to 10.668 m)
4*
■
How Many Connectors?
Use the chart at left to determine the proper number
of 6" (152 mm) connectors for your headstay.
Every unit uses one 7
5
/
8
" (194 mm) bottom connector
in
addition to
the number of 6" (152 mm) connectors
shown at left.
*One additional connector required; order part #909
■
How Many Foils?
Use the chart at left to determine the proper number
of 7' (2.13 m) foils for your headstay.
The variable length top foil is cut from one of the 7'
(2.13 m) foils and is used
in addition
to the number
of foils shown at left.
*One additional foil required; order part 1112.
■
Stringing Connectors
After the headstay has been cut to length, but
before
the
lower terminal is attached, the proper number of con-
nectors must be placed on the headstay in the correct
order.
Every unit uses a top foil trim cap.
Every unit uses a number of 6" (152 mm) connectors
which varies according to the length of the headstay
and is determined by consulting the chart above.
Every unit uses one 7
5
/
8
" (194 mm) bottom connector.
Slide the trim cap onto the stay so that the open end
faces down.
Slide the proper number of 6" (152 mm) connectors
onto the headstay.
Slide the 7
5
/
8
" (194 mm) bottom connector onto the
headstay so that it is closest to the bottom of the
headstay.
Have the wire swaged by a reputable rigger.
.ORSEMAN3TA,OK)NSTRUCTIONS
"ECAUSE.ORSEMANAND3TA,OKTERMINALSAREAPPLIEDTOTHE
HEADSTAYWIREAFTERTHEFOILISBUILTITISNOTNECESSARYTOPLACE
THECONNECTORSORTRIMCAPONTHEWIREATTHISTIME
.ORSEMANAND3TA,OKUNITSREQUIRETHESAMENUMBEROFFOILS
ANDCONNECTORSASSHOWNABOVE)DENTIFYTHEPARTSYOUNEED
ANDSETTHEMASIDEATTHISTIME
2OD)NSTRUCTIONS
2ODINSTALLATIONSAREIDENTICALTOSWAGEDWIREATTHISPOINT
EXCEPTTHATTHERODFITTINGISCOLDHEADEDTOTHERODRATHERTHAN
SWAGEDON
)FYOUSHIPARODHEADSTAYTOASERVICECENTERDONOTCOILTIGHTER
THANTIMESTHERODgSDIAMETER