7
0,1,2
Operation
(see page 71)
Hansgrohe recommends not to use as drinking water the first half litre
flowing from the tap in the morning, after the hygiene rinse is enabled,
or after prolonged non-use. The hygiene rinse opens the tap for 10
seconds every 24 hours following the last operation.
Hygienerinse
To enable or disable the hygiene rinse, proceed as follows:
• Interrupt voltage supply of the fittings for approx. 10 s (disconnect
electrical plug connection between fittings and battery housing or
power pack and reconnect after 10 s)
• The LED blinks to indicate the software version (e.g. blinking once =
software version 1)
• permanent light from the LED indicates that calibration of the infra-
red proximity electronics is in progress
• wait for LED to go out
• cover sensor window completely with your hand or a white piece
of paper
• Remove your hand or the paper after 10 s
• the currently enabled mode is indicated by the flashing of the LED:
1 x = enabled, 2 x = disabled
Permanentrinse
After setting the parameters for the hygiene rinse or making a net
reset, wait for approx. 90 s before you can enable the "Permanent
rinse" function.
• cover sensor window completely with your hand or a white piece
of paper
• The tap opens briefly and then closes immediately. When the tap
opens again after approx. 5 s, remove the hand or the paper from
the sight glass.
• Permanent rinse is enabled for approx. 180 s and can be inter-
rupted at any time by a movement in the field of vision.
Thermaldisinfection
• Thermal disinfection pursuant to process sheet DVGW W 551(≥
70°C / > 3 min) must only be carried out by qualified personnel.
• Risk of scalding with thermal disinfection!
• The cold water feed must be locked during thermal disinfection.
Afterwards, "Permanent rinse" can be enabled.
Netreset
(see page 77)
A net reset causes the fittings to re-adjust
Cleaningwashbasin
(see page 71)
Connectingcablebetweenfitting/transformer
Cable length:
7 m
Wire cross section:
ca. 0,25 mm²
- Wire color:
black (GND)
+ Wire color:
red (6 V DC)
Connection on the transformer:
Clamp connection
Empty conduit for cable:
EN 20
If the connecting cable is shortened, it must be fitted with 0.25 mm² wire end plugs
and a contact length of 8 mm.
Symboldescription
Do not use silicone containing acetic acid!
transformer
Empty pipe
230 V
Dimensions
(see page 60)
Protectedarea
(see page 61)
Water connection DN20 Cold water
Cleaning
see enclosed brochure
6 V
Water connection DN20 Warm water
Flowdiagram
(see page 60)
with EcoSmart
®
without EcoSmart
®
Specialaccessories
(see page 76) order as an extra
Extension Set 22 mm (when wall is not deep enough). #13596000
Adjustment
(see page 70)
Set the desired maximum temperature for hot water
Testcertificate
(see page 80)
Spareparts
(see page 76)
Maintenance
(see page 72)
The check valves must be checked regularly according to DIN EN
1717 in accordance with national or regional regulations (at least
once a year).
Assemblyseepage70
English
Summary of Contents for AXOR Uno 45110000
Page 62: ...62 SW 17 mm SW 24 mm SW 4 mm 90 90 2 3 1 Montage ...
Page 63: ...63 5 7 SW 5 mm 90 SW 4 mm SW 4 mm 90 90 4 6 ...
Page 64: ...64 SW 5 mm 8 Nm SW 4 mm SW 4 mm 90 90 8 9 10 ...
Page 65: ...65 12 12 13 SW 24 mm 1 mm 1 mm 15 SW 3 mm 14 11 ...
Page 66: ...66 16 17 12 30 M4x30 30 40 M4x45 18 19 20 SW 3 mm 4 Nm SW 3 mm 1 2 ...
Page 68: ...68 SW 5 mm 31 SW 4 mm 5 Nm 32 30 28 29 27 2 1 ...
Page 69: ...69 90 34 SW 4 mm 33 35 90 36 ...
Page 70: ...70 0 1 Nm 37 38 39 40 SW 3 mm ca 30 sec 41 X X 11 1 2 mm 1 2 Justierung ...
Page 71: ...71 1 ca 10 sec ca 60 sec 2 3 10 20 mm Bedienung ...
Page 72: ...72 4 5 2 3 SW 4 mm 1 SW 4 mm 90 90 Wartung ...
Page 74: ...74 12 13 11 SW 4 mm A B 90 90 ...
Page 75: ...75 H C D E SW 3 mm SW 3 mm 6 Nm G F 1 2 ...
Page 78: ...78 ...
Page 79: ...79 ...