47
5.1.8
Cavitation
Table 18.
Cavitation SCR Table
SYMPTOM
CAUSE
REMEDY
Pump Is Cavitating
Discharging More Water
Than The Pump Is Taking In
Increase the flow into the pump with more
and/or larger intake lines.
Gate the discharge valves to reduce flow and
maintain pressure.
Air Leak
Verify air bleeder on the suction tube is not
open.
Locate and eliminate all air leaks during
maintenance.
Drafting Too High
Verify lift loss, hose friction, water tempera-
ture and other lift limiting factors are reduced
or eliminated.
Locate the pump closer to the water source.
Water Temperature Too
High
Reduce volume discharged by lowering RPM
or gating the discharge valves.
Locate a source of cooler water.
Table 19.
Rotation SCR Table
SYMPTOM
CAUSE
REMEDY
Reduced Pressure To
60—100 psi And Reduced
Flow
Wrong Impeller Installed
See Figure 12
Verify the new impeller vanes are oriented
the same as the old impeller before installa-
tion. See Figure 12.
Wrong Application
The pump was installed on an application for
which it was not intended i.e. front mount vs.
rear mount.
It is possible to reassemble the pump incorrectly or with the wrong parts. Always compare the
replacement parts with the original hardware. (See Figure 12.)
Figure 13. Engine Or Opposite Engine Rotation
Summary of Contents for AP
Page 2: ......
Page 28: ......
Page 71: ...59 Figure 19 One Piece Volute AP CBP MBP Figure 20 Three Piece Volute RSD...
Page 73: ...61 Figure 21 AP Pump Exploded View...
Page 74: ...62 Figure 22 CBP Pump Exploded View...
Page 75: ...63 Figure 23 MBP Pump Exploded View...
Page 76: ...64 Figure 24 RSD Pump Exploded View...
Page 77: ...65 Figure 25 Gearbox Exploded View All Except 3 74 1 GR...
Page 78: ...66 Figure 26 Gearbox Exploded View 3 74 1 GR...
Page 158: ...146 THIS PAGE INTENTIONALLY BLANK...
Page 174: ...C 12 THIS PAGE INTENTIONALLY BLANK...
Page 176: ...D 2 DATE HOURS RUN MAINTENANCE PROBLEM PART S USED REASON REPLACED INITIALS...