15
2.6.2
TRVs
Hale optional offers a thermal relief valve in two temperature ranges and with remote indication.
•
TRV–120
•
TRV–170
•
TRV–L
The TRV is a thermal relief valve that acts as a thermostat and opens when the temperature of
the water in the pump exceeds 120
℉
(TRV–120) or 170
℉ (TRV
–170)
and
resets (closes)
when the water cools. The RSD utilizes the standard Hale 115 series flange opening located on
the side of the volute (K port) and a flange adaptor to house the TRV. For all other Flex series
booster pumps the TRV must be installed on a fabricated manifold and similar application and
the installer is to provide 1-1/4-in NPT opening and install the TRV close to the volute discharge
port. The TRV discharge water should be directed to the ground or back to the booster tank, help-
ing to keep the pump cool and avoiding premature wear and damage.
The TRV–L is a TRV (120
℉
or 170
℉
) with the added feature of a remoted indicator (audible
and visual) panel to show when the TRV is open and flowing water. The indicator panel also has
an integral test switch.
Summary of Contents for AP
Page 2: ......
Page 28: ......
Page 71: ...59 Figure 19 One Piece Volute AP CBP MBP Figure 20 Three Piece Volute RSD...
Page 73: ...61 Figure 21 AP Pump Exploded View...
Page 74: ...62 Figure 22 CBP Pump Exploded View...
Page 75: ...63 Figure 23 MBP Pump Exploded View...
Page 76: ...64 Figure 24 RSD Pump Exploded View...
Page 77: ...65 Figure 25 Gearbox Exploded View All Except 3 74 1 GR...
Page 78: ...66 Figure 26 Gearbox Exploded View 3 74 1 GR...
Page 158: ...146 THIS PAGE INTENTIONALLY BLANK...
Page 174: ...C 12 THIS PAGE INTENTIONALLY BLANK...
Page 176: ...D 2 DATE HOURS RUN MAINTENANCE PROBLEM PART S USED REASON REPLACED INITIALS...