72
5.8.4.3
AP/MBP Volute R&R
In addition to gasket/O-ring failure the volute requires removal to examine or access internal
pump components (clearance rings, impeller, mechanical seal, etc.). See Figure 26 for AP volute
removal. Typically the volute would not require replacement unless it has been damaged by al-
lowing the pump to freeze with water in it or a large piece of debris was allowed into the pump by
not using or maintaining strainers.
Figure 27. AP/MBP Volute R&R
Refer to Table 27 for a list of tools and/or consumables required for this procedure.
Table 27.
AP Volute R&R Tools And Consumables List
Standard Tools
Special Tools
Consumables
PPE
(Eye and Hand Protection)
None
Shop Rag(s) (As Required)
Gasket Scrapper
O-ring Lubricant (See Table 20 )
Hooked-end Dental Pick
(or Hose Removal Tool)
O-RING, <See FSG–PL–01483 Sheet 4 Item 7>
(Volute to Pump Head)
5/8-in Wrench
(Or Ratchet Wrench)
(Or Pass Thru Ratchet)
Gasket <See FSG–PL–01483 Sheet 4 Item 6>
(Volute to Pump Head)
5/8-in Torque Wrench
Volute: (ONLY ONE REQUIRED – SELECT FROM: )
<See FSG–PL–01483 Sheet 4 Item 1>
Loctite™ Clean-Up Solvent
Loctite™ 243 (Or Equivalent)
Summary of Contents for AP
Page 2: ......
Page 28: ......
Page 71: ...59 Figure 19 One Piece Volute AP CBP MBP Figure 20 Three Piece Volute RSD...
Page 73: ...61 Figure 21 AP Pump Exploded View...
Page 74: ...62 Figure 22 CBP Pump Exploded View...
Page 75: ...63 Figure 23 MBP Pump Exploded View...
Page 76: ...64 Figure 24 RSD Pump Exploded View...
Page 77: ...65 Figure 25 Gearbox Exploded View All Except 3 74 1 GR...
Page 78: ...66 Figure 26 Gearbox Exploded View 3 74 1 GR...
Page 158: ...146 THIS PAGE INTENTIONALLY BLANK...
Page 174: ...C 12 THIS PAGE INTENTIONALLY BLANK...
Page 176: ...D 2 DATE HOURS RUN MAINTENANCE PROBLEM PART S USED REASON REPLACED INITIALS...