background image

Installation, Operation &

Maintenance Manual

Submersible Solids

Handling Pumps

IMPORTANT! - Read all instructions in this manual before operating or servicing 
a pump.

2BSE51SS

0.5 HP

2BSE72SS

2BSE73SS

2BSE74SS

0.75 HP

3BSE102SS

3BSE103SS

3BSE104SS

1 HP

Last update: 03/11/2021

2BSE-SS &

3BSE-SS

0.5, 0.75 & 1 HP @ 1750 RPM

barmesa.com

Summary of Contents for 2BSE-SS

Page 1: ...Handling Pumps IMPORTANT Read all instructions in this manual before operating or servicing a pump 2BSE51SS 0 5 HP 2BSE72SS 2BSE73SS 2BSE74SS 0 75 HP 3BSE102SS 3BSE103SS 3BSE104SS 1 HP Last update 03...

Page 2: ...ms associatedwithornearthepump T h i s p u m p i s n o t i n t e n d e d f o r u s e i n swimming pools or water installations where there is DANGER humancontactwithpumpedfluid Riskofelectric shock To...

Page 3: ...the model to 3BSE SS 2 discharge flange is available for these models this change the model to 2BSE SS 02 Specifications DISCHARGE 2 or3 NPTfemale vertical boltonflange SPHERICALSLDHNDLG 2 LIQUIDTEMP...

Page 4: ...the top of the motor housing or a minimum level of 10 inches above the basin floor 4Electrical Connections Power cable The power cable mounted to the pump must not be modified in any way except for sh...

Page 5: ...ee from suspended particles Milky white oil indicates the presence of water Oil level should be just above the motor when pump is in vertical position Oil Testing Drain oil into a clean dry container...

Page 6: ...much pressure will damage seal DO NOT exceed 10 PSI DO NOT overfill oil Overfilling of housing with oil can create excessive and dangerous hydraulic pressure which can destroy the pump and create a h...

Page 7: ...or equivalent to shaft threads Screw impeller onto shaft hand tight while using a screwdriver in the slot at the end of the shaft to hold it stationary Rotate impeller to check for binding 12 Place g...

Page 8: ...PHASE 208 230V AC POWER CORD 4x12 G T1 T7 T2 T8 T3 T9 T4 T5 T6 G L1 L2 L3 GREEN BLACK RED WHITE MOTOR LEADS Cable motor line Green Green Black 1 7 Red 2 8 White 3 9 4 5 6 together Three phase 230 VAC...

Page 9: ...08 Repair Parts Figure 5 For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List barmesa com...

Page 10: ...1 2 DISHARGE 1 HT200 22 HEX SOCKET CAP SCREWS 1 4 20UNC x 28 2 SS 304 23 V SHAPE RING 1 NBR 40 24 MECHANICAL SEAL 31 8 x 15 9 x 32 5 1 SiC SiC 25 ELLASTIC COLLAR 40 1 65Mn 26 ELLASTIC COLLAR 17 1 65Mn...

Page 11: ...Check all electrical connections for security Have electrician measure current in motor leads if current is within 20 of locked rotor Amps impeller is probably locked If current is 0 overload may be t...

Page 12: ...impaired 10 Impeller rotation is incorrect 12 Piping attachments to build dtructure too loose or rigid 15 POSSIBLE CAUSE D Pump delivers insufficient capacity 9 Open the valve 10 Check the impeller so...

Page 13: ......

Reviews: