background image

Read this manual before use of product

IWAKI Magnetic Drive Pump

MX-F100 (Asia Edition)

Instruction Manual

Summary of Contents for MX-F100

Page 1: ...Read this manual before use of product IWAKI Magnetic Drive Pump MX F100 Asia Edition Instruction Manual...

Page 2: ...e prevention of personal injury or property damage Observe the instructions accompanied with WARNING or CAUTION in this manual These instructions are very impor tant for protecting pump users from dan...

Page 3: ...damage due to modification Wear protective clothing Always wear protective clothing such as safety goggles and protective gloves during pipework or dismantlement Restriction on operator The pump shoul...

Page 4: ...le is not replaceable Do not use any damaged power cable for the prevention of a fire or an electrical shock The cable is not replaceable so that the whole pump unit needs to be replaced when the cabl...

Page 5: ...inlet to outlet Before use check the specification limitation and hazardous nature of the pump 1 Unpacking Inspection On unpacking the product check the following points If you find any problems cont...

Page 6: ...MX F100 M FL G1 25A NOTE a Performance data is based on pumping of clear water at ambient temperature b Allowable liquid temperature is 0 80 C non freezing Note that the temperature range may change w...

Page 7: ...5 5 Outer dimensions MX F100M MX F100FL Outline 4 9 4 27 162 70 90 150 110 175 75 100 51 65 319 5 65 107 327 90 169 70 25A 25A 182 75 150 110 51 4 9 4 27...

Page 8: ...nits 7 Overview Label Inlet Base Fix the pump securely Specification label Use the pump accord ing to the specifica tions on the label Outlet Pump unit Liquid feeding unit Not capable of self priming...

Page 9: ...1 Alumina ceramics The MX F100KV has two impeller thrust rings No Part names Q ty Materials MX F100RV MX F100KV 10 Rear thrust ring 1 Alumina ceramics SiC 11 Driven magnet 1 12 Drive magnet unit 1 13...

Page 10: ...mics The MX F100KV has two impeller thrust rings No Part names Q ty Materials MX F100RVFL 11 Drive magnet 1 12 Drive magnet unit 1 Ferrite magnet Aluminium alloy 13 Driven magnet 1 14 Hex sock set scr...

Page 11: ...is heated or loaded with a heavy thing 1 Before Installation Read through this section before use Carry out installation work with a full understanding WARNING Risk of electrical shock Turn off power...

Page 12: ...with any liquid which contains metals such as iron and nickel Do not clean the pump and nameplate with solvent such as benzine and thin ner This may discolour the pump or erase printing Use a dry clot...

Page 13: ...rings exces sively if a liquid level in a supply tank is too low 3 Outlet direction Always direct the outlet upward or entrained air can not be expelled CAUTION Do not mount the pump vertically direct...

Page 14: ...ON Be careful not to drop the pump onto the floor A strong impact may reduce pump performance Discharge side valve Suction side valve Installation Thread connection Wrap a thread seal tape around the...

Page 15: ...g the recommended wiring accessories 3 Apply the specified power voltage See the spec label 4 The pump doesn t have the ON OFF switch The pump starts as the power cable is plugged in 5 Earth the pump...

Page 16: ...2 and 3 Then turn on power and start the pump If the pump chamber is not filled enough conduct degassing See page 15 for detail Operation 1 Before operation Read through this section before use CAUTIO...

Page 17: ...ked during operation Do not allow foreign matters to enter the pump Foreign matters may cause impeller to be locked hindering liquid circulation In this case turn off power immediately Contact us Turn...

Page 18: ...Check if the motor stops rotating smoothly as turning off power If it is not smooth check the motor Contact us for detail Before a long period of stoppage Empty the pump before it is stopped for a lo...

Page 19: ...t us or your nearest dealer as necessary 2 Maintenance Inspection Retightening After a long period of operation or storage the pump head mount ing screws may loosen Tighten uniformly the mounting scre...

Page 20: ...ump does not have a drain port See next procedure for detail WARNING Turn off power before work Wear protective clothing such as safety goggles and protective gloves when handling harmful liquid CAUTI...

Page 21: ...in IWAKI Iberica Pumps S A TEL 34 943630030 FAX 943628799 China GFTZIWAKIEngineering Trading Beijing TEL 86 1064427713 FAX 1064427712 Sweden IWAKI Sverige AB TEL 46 851172900 FAX 851172922 Denmark IWA...

Reviews: