background image

ITEM

DESCRIPTION

QTY. MATERIAL

1

CABLE ASSEMBLY (14AWG-3)

1

SOW

2

O-RING Ø45 x 3.1

1

NBR 40

3

PUMP BODY

1

HT200

4

CAPACITOR 30µ F/300V 90°C

1

ALUMINIUM

5

UPPER BEARING PLATE

1

ZL102

6

BEARING 6203

2

-

7

WAVE WASHER

39

65Mn

8

TEMPERATURE PROTECTOR

1

-

9

STATOR

1

-

10 ROTOR COMPONENT

1

-

11 STATOR COMPONENT

1

-

12 HEX. HEAD BOLT 5/16"-18UNC x 4"

4

SS 304

13 SPRING WASHER

8

SS 304

14 LOWER BEARING PLATE O-RING Ø192 x Ø199 x 35

1

NBR 40

15 LOWER BEARING PLATE

1

HT200

16 IMPELLER Ø131.5

1

HT200

17 THIN NUT 1/2"-20 UNF

1

2Cr13

18 CASING

1

HT200

19 CASING SEALING WASHER

1

RUBBER

20 DISCHARGE SEALING WASHER

1

NBR 40

21 2" DISHARGE

1

HT200

22 HEX. SOCKET CAP SCREWS 1/4"-20UNC x 28

2

SS 304

23 "V" SHAPE RING

1

NBR 40

24 MECHANICAL SEAL Ø31.8 x Ø15.9 x 32.5

1

SiC/SiC

25 ELLASTIC COLLAR 40

1

65Mn

26 ELLASTIC COLLAR 17

1

65Mn

27 LENGTHEN BOLT #8-32 x 140

4

Q235A

28 FLAT WASHER 4

4

Q235A

29 SPRING WASHER 4

4

65Mn

30 CAPACITOR CLAMP

1

08F

31 CROSS RECESSED PAN HEAD SCREW M4 x 8

2

Q235A

32 GROUND LEAD

1

-

33 HEX. BOLT 5/16"-18UNC x 25

4

SS 304

34 HEX. SOCKET PIPE PLUG 3/8"-18 NPT

1

SS 304

35 HANDLE

1

SS 304

36 NAME PLATE

1

SS 304

37 NAIL FOR NAME PLATE Ø2 x 4

4

Cu

38 HEX. HEAD BOLT 3/8"-16UNC x 22

2

SS 304

39 SPRING WASHER 10

2

SS 304

40 TRADEMARK SIGN

1

SS 304

10

Parts List

For  Repair  Part  Please  supply:  Model  Number  and  Serial  as  shown  on 
Name Plate, and Part Description and Part Number as shown on Parts List.

barmesa.com

Summary of Contents for 2BSE-SS

Page 1: ...Handling Pumps IMPORTANT Read all instructions in this manual before operating or servicing a pump 2BSE51SS 0 5 HP 2BSE72SS 2BSE73SS 2BSE74SS 0 75 HP 3BSE102SS 3BSE103SS 3BSE104SS 1 HP Last update 03...

Page 2: ...ms associatedwithornearthepump T h i s p u m p i s n o t i n t e n d e d f o r u s e i n swimming pools or water installations where there is DANGER humancontactwithpumpedfluid Riskofelectric shock To...

Page 3: ...the model to 3BSE SS 2 discharge flange is available for these models this change the model to 2BSE SS 02 Specifications DISCHARGE 2 or3 NPTfemale vertical boltonflange SPHERICALSLDHNDLG 2 LIQUIDTEMP...

Page 4: ...the top of the motor housing or a minimum level of 10 inches above the basin floor 4Electrical Connections Power cable The power cable mounted to the pump must not be modified in any way except for sh...

Page 5: ...ee from suspended particles Milky white oil indicates the presence of water Oil level should be just above the motor when pump is in vertical position Oil Testing Drain oil into a clean dry container...

Page 6: ...much pressure will damage seal DO NOT exceed 10 PSI DO NOT overfill oil Overfilling of housing with oil can create excessive and dangerous hydraulic pressure which can destroy the pump and create a h...

Page 7: ...or equivalent to shaft threads Screw impeller onto shaft hand tight while using a screwdriver in the slot at the end of the shaft to hold it stationary Rotate impeller to check for binding 12 Place g...

Page 8: ...PHASE 208 230V AC POWER CORD 4x12 G T1 T7 T2 T8 T3 T9 T4 T5 T6 G L1 L2 L3 GREEN BLACK RED WHITE MOTOR LEADS Cable motor line Green Green Black 1 7 Red 2 8 White 3 9 4 5 6 together Three phase 230 VAC...

Page 9: ...08 Repair Parts Figure 5 For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List barmesa com...

Page 10: ...1 2 DISHARGE 1 HT200 22 HEX SOCKET CAP SCREWS 1 4 20UNC x 28 2 SS 304 23 V SHAPE RING 1 NBR 40 24 MECHANICAL SEAL 31 8 x 15 9 x 32 5 1 SiC SiC 25 ELLASTIC COLLAR 40 1 65Mn 26 ELLASTIC COLLAR 17 1 65Mn...

Page 11: ...Check all electrical connections for security Have electrician measure current in motor leads if current is within 20 of locked rotor Amps impeller is probably locked If current is 0 overload may be t...

Page 12: ...impaired 10 Impeller rotation is incorrect 12 Piping attachments to build dtructure too loose or rigid 15 POSSIBLE CAUSE D Pump delivers insufficient capacity 9 Open the valve 10 Check the impeller so...

Page 13: ......

Reviews: