Troubleshooting Chart
SYMPTOM
CORRECTIVE ACTION
Incorrect low voltage.
(1)
Discharge restricted.
(7)
Check valve is partially
closed or installed
backward.
(8)
Shut-off valve closed.
(9)
The impeller is jammed or
the shaft is loose, worn or
damaged, or inlet
plugged.
(10)
Pump may be air locked
casuing pump not to flow.
(11)
Pumprunning backwards.
(12)
Check valve is partially
closed or installed
backward.
(8)
fixtures are leaking.
(13)
Groundwater is entering
basin.
(17)
Wiring or electrical current
is inappropriate.
(1)
The total dynamic charge
is below the
recommended minimum.
(6)
Impeller is jammed or
bounds near the pump
body.
(10)
Excessive water
temperature (internal
protection only).
(14)
Worn bearings, the motor
shaft bent.
(4)
Obstruction in the cavity
of the impeller or is
impaired.
(10)
Impeller rotation is
incorrect.
(12)
Piping attachments to
build dtructure too loose
or rigid.
(15)
POSSIBLE CAUSE
D) Pump delivers insufficient
capacity.
(9)
Open the valve.
(10)
Check the impeller so that it rotates freely. Clean
the cavity of the impeller and the suction of the pump
body by removing any obstructions.
(11)
Loosen union slightly to allow trapped air to
escape. Verify that turn-off level of switch is set so
that the suction is always flooded. Clean vent hole.
(12)
Check rotation. If power supply is three phase,
reverse any two of three power supply leads to
ensure proper impeller rotation.
(13)
Repair fixtures as required to eliminate leakage.
(14)
Check the temperature of the liquid to be
pumped, which must not exceed 160 ° F ( 71 ° C).
(15)
Replace portion of discharge pipe with flexible
connector or tighten existing piping..
(16)
Turn to automatic position.
(17)
Check for leaks around basin inlet and outlets.
E) The pump turns on and off
very frequently (more than
usual).
F) The pump goes off and on
regardless of the switch and
activates the thermal overload
protector .
CAUTION!
, the
pump may start unexpectedly.
Disconnect power supply.
G) Pump operates noisily or
vibrates excessively.