Barmesa Pumps 2BSE-SS Installation, Operation & Maintenance Manual Download Page 12

NOTE: 

Barmesa Pumps assumes no responsibility for damage or injury due to disassembly in the field. Disassembly of the pumps or supplied accessories other 

than at Barmesa Pumps or its authorized service centers, automatically voids warranty.

12

Troubleshooting Chart

SYMPTOM

CORRECTIVE ACTION

Incorrect low voltage.

(1)

Discharge restricted.

(7)

Check valve is partially 
closed or installed 
backward.

(8)

Shut-off valve closed.

(9)

The impeller is jammed or 
the shaft is loose, worn or 
damaged, or inlet 
plugged.

(10)

Pump may be air locked 
casuing pump not to flow.

(11)

Pumprunning backwards.

(12)

Check valve is partially 
closed or installed 
backward.

(8)

fixtures are leaking.

(13)

Groundwater is entering 
basin.

(17)

Wiring or electrical current 
is inappropriate.

(1)

The total dynamic charge 
is below the 
recommended minimum.

(6)

Impeller is jammed or 
bounds near the pump 
body.

(10)

Excessive water 
temperature (internal 
protection only).

(14)

Worn bearings, the motor 
shaft bent.

(4)

Obstruction in the cavity 
of the impeller or is 
impaired.

(10)

Impeller rotation is 
incorrect.

(12)

Piping attachments to 
build dtructure too loose 
or rigid.

(15)

POSSIBLE CAUSE

D) Pump delivers insufficient 
capacity.

(9)

 Open the valve.

(10)

 Check the impeller so that it rotates freely. Clean 

the cavity of the impeller and the suction of the pump 
body by removing any obstructions.

(11)

 Loosen union slightly to allow trapped air to

escape. Verify that turn-off level of switch is set so 
that the suction is always flooded. Clean vent hole.

(12)

 Check rotation. If power supply is three phase, 

reverse any two of three power supply leads to 
ensure proper impeller rotation.

(13)

 Repair fixtures as required to eliminate leakage.

(14)

 Check the temperature of the liquid to be 

pumped, which must not exceed 160 ° F ( 71 ° C).

(15)

 Replace portion of discharge pipe with  flexible 

connector or tighten existing piping..

(16)

 Turn to automatic position.

(17)

 Check for leaks around basin inlet and outlets.

E) The pump turns on and off 
very frequently (more than 
usual).

F) The pump goes off and on 
regardless of the switch and 
activates the thermal overload 
protector . 

CAUTION!

, the 

pump may start unexpectedly. 
Disconnect power supply.

G) Pump operates noisily or 
vibrates excessively.

barmesa.com

Summary of Contents for 2BSE-SS

Page 1: ...Handling Pumps IMPORTANT Read all instructions in this manual before operating or servicing a pump 2BSE51SS 0 5 HP 2BSE72SS 2BSE73SS 2BSE74SS 0 75 HP 3BSE102SS 3BSE103SS 3BSE104SS 1 HP Last update 03...

Page 2: ...ms associatedwithornearthepump T h i s p u m p i s n o t i n t e n d e d f o r u s e i n swimming pools or water installations where there is DANGER humancontactwithpumpedfluid Riskofelectric shock To...

Page 3: ...the model to 3BSE SS 2 discharge flange is available for these models this change the model to 2BSE SS 02 Specifications DISCHARGE 2 or3 NPTfemale vertical boltonflange SPHERICALSLDHNDLG 2 LIQUIDTEMP...

Page 4: ...the top of the motor housing or a minimum level of 10 inches above the basin floor 4Electrical Connections Power cable The power cable mounted to the pump must not be modified in any way except for sh...

Page 5: ...ee from suspended particles Milky white oil indicates the presence of water Oil level should be just above the motor when pump is in vertical position Oil Testing Drain oil into a clean dry container...

Page 6: ...much pressure will damage seal DO NOT exceed 10 PSI DO NOT overfill oil Overfilling of housing with oil can create excessive and dangerous hydraulic pressure which can destroy the pump and create a h...

Page 7: ...or equivalent to shaft threads Screw impeller onto shaft hand tight while using a screwdriver in the slot at the end of the shaft to hold it stationary Rotate impeller to check for binding 12 Place g...

Page 8: ...PHASE 208 230V AC POWER CORD 4x12 G T1 T7 T2 T8 T3 T9 T4 T5 T6 G L1 L2 L3 GREEN BLACK RED WHITE MOTOR LEADS Cable motor line Green Green Black 1 7 Red 2 8 White 3 9 4 5 6 together Three phase 230 VAC...

Page 9: ...08 Repair Parts Figure 5 For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List barmesa com...

Page 10: ...1 2 DISHARGE 1 HT200 22 HEX SOCKET CAP SCREWS 1 4 20UNC x 28 2 SS 304 23 V SHAPE RING 1 NBR 40 24 MECHANICAL SEAL 31 8 x 15 9 x 32 5 1 SiC SiC 25 ELLASTIC COLLAR 40 1 65Mn 26 ELLASTIC COLLAR 17 1 65Mn...

Page 11: ...Check all electrical connections for security Have electrician measure current in motor leads if current is within 20 of locked rotor Amps impeller is probably locked If current is 0 overload may be t...

Page 12: ...impaired 10 Impeller rotation is incorrect 12 Piping attachments to build dtructure too loose or rigid 15 POSSIBLE CAUSE D Pump delivers insufficient capacity 9 Open the valve 10 Check the impeller so...

Page 13: ......

Reviews: