5.3 LOW PRESSURE ALARM
´
Alarm 179 (Low Pressure Transmission Oil) has been triggered.
l
Check for low oil supply in reservoir.
l
Check to see that pump motor is running.
l
Check for an air leak in the suction side of the pump.
l
Check for a bad pressure sensor.
l
Check for a broken or damaged cable.
l
Check for a worn pump head.
6. THROUGH THE SPINDLE COOLANT
6.1 COOLANT OVERFLOW
To begin troubleshooting, check the alarm history to determine the problems cause before any action is taken.
´
Coolant pouring out of spindle head covers.
l
Check for seal failure. If failure is found, replace the seal (seal / housing assy. kit #93-9000). Refer to the appropriate
steps in"TSC-Tool Release Piston Replacement" section for procedure.
l
Check that the TSC drain line is intact. If necessary, replace with 5/32" O.D. X 32" long nylon tubing (24" long for VF-
O/OE)
l
Check pre-charge pressure in accordance with TSC "Pressure Regulator Adjustment' section and reset if necessary.
Low pre-charge pressure can cause coolant to dump into the spindle head.
l
Ensure the coolant pump relief valve has not been tampered with. (yellow paint band is intact). Check the coolant
pump pressure (should be 140 psi), with a standard tool holder in spindle. If pump pressure is above 140 psi, reset
the pump relief valve in accordance with the "Setting TSC Pump Relief Valve" section.
´
Excessive coolant flow out of drain line.
´
Pulsating flow through tool and drain line.
l
Check pre-charge pressure in accordance with TSC "Pressure Regulator Adjustment" section. Reset precharge
pressure if necessary. Low pre-charge pressure will cause heavy or pulsating flow from the drain line.
l
Ensure the coolant pump relief valve has not been tampered with (yellow paint band is intact). Check the coolant pump
pressure (should be 140 psi), with a standard tool holder in spindle. If pump pressure is above 140 psi, reset pump
relief valve in accordance with "Setting Pump Relief Valve" section.
6.2 LOW COOLANT
´
Alarm 151, "Low Thru Spindle Coolant"
l
Check coolant tank level. Check the filter and intake strainer for any clogging. Check coolant lines for any clogging
or kinking. Clean or replace as needed.
l
If received at start-up, check that the breaker hasn't tripped and that the pump is turning. Check the electrical
continuity of cables.
Summary of Contents for VF-SERIES
Page 180: ...1 15 96 96 8100 177 TABLEOFCONTENTS TECHNICAL REFERENCE SERVICE M A N U A L VF SERIES ...
Page 235: ...96 8100 1 15 96 232 VF SERIES S E R V I C E M A N U A L ASSEMBLY DRAWINGS VF 1 COLUMN ...
Page 237: ...96 8100 1 15 96 234 VF SERIES S E R V I C E M A N U A L ASSEMBLY DRAWINGS VF 1 LEADSCREW ...
Page 239: ...96 8100 1 15 96 236 VF SERIES S E R V I C E M A N U A L ASSEMBLY DRAWINGS VF 3 COLUMN ...
Page 241: ...96 8100 1 15 96 238 VF SERIES S E R V I C E M A N U A L ASSEMBLY DRAWINGS VF 3 LEADSCREW ...
Page 245: ...96 8100 1 15 96 242 VF SERIES S E R V I C E M A N U A L ASSEMBLY DRAWINGS 3 4 2 1 ...