1-15-96
96-8100
HAAS
AUTOMATION, INC.
111
MECHANICAL SERVICE
S E R V I C E M A N U A L
VF-S
ERIES
Fig. 14-3 View of gap between front of door and front panel flange.
SWITCH ADJUSTMENT -
12. Move the door to the fully closed position. Go to the "Diagnostics" page on the control panel, and ensure
"DOOR S" reads "0". Move the door to the open position, and ensure "DOOR S" reads "1". If either reading is incorrect:
Ø
Loosen the SHCS that mounts the switch actuator bracket to the top of the door.
NOTE:
It is possible
to access this bracket from the side window.
Ø
Move the bracket in its slot to the proper position and tighten the SHCS.
14.2 WINDOW REPLACEMENT
REMOVAL -
1. Turn the machine power off.
2. Move the door to the fully closed position so the window is accessible. Use a trim installation tool to pull the
locking tab out of the inside of the window seal (the tab is a part of the seal).
3. Remove the window panel from the seal. The tool can be placed between the window panel and the seal to aid in
removing the window panel.
4. Remove the seal from the enclosure's cutout.
Fig. 14-4 Cross-section of window seal.
Summary of Contents for VF-SERIES
Page 180: ...1 15 96 96 8100 177 TABLEOFCONTENTS TECHNICAL REFERENCE SERVICE M A N U A L VF SERIES ...
Page 235: ...96 8100 1 15 96 232 VF SERIES S E R V I C E M A N U A L ASSEMBLY DRAWINGS VF 1 COLUMN ...
Page 237: ...96 8100 1 15 96 234 VF SERIES S E R V I C E M A N U A L ASSEMBLY DRAWINGS VF 1 LEADSCREW ...
Page 239: ...96 8100 1 15 96 236 VF SERIES S E R V I C E M A N U A L ASSEMBLY DRAWINGS VF 3 COLUMN ...
Page 241: ...96 8100 1 15 96 238 VF SERIES S E R V I C E M A N U A L ASSEMBLY DRAWINGS VF 3 LEADSCREW ...
Page 245: ...96 8100 1 15 96 242 VF SERIES S E R V I C E M A N U A L ASSEMBLY DRAWINGS 3 4 2 1 ...