96-8100
1-15-96
114
MECHANICAL SERVICE
HAAS
AUTOMATION, INC.
S E R V I C E M A N U A L
VF-S
ERIES
Fig. 15-1 Hydraulic Counterbalance view.
NOTE:
If there is an E-stop alarm that will not reset, check for correct system pressure and the correct tank
assembly.
15.2 HYDRAULIC CYLINDER REPLACEMENT
Removal -
1. Remove the hydraulic tank as described in previous section.
2. To gain access to the cylinder rod, remove the three SHCS holding the Z-axis way cover to the spindle head.
3. Remove the cotter pin and lock nuts from the threaded end of the cylinder rod.
4. Loosen the two SHCS holding the cylinder clamp to the column, and the bracket screw, and remove both.
5. Remove the hydraulic cylinder from the top of the column.
NOTE:
Do not disassemble unit. Keep the hose attached to the cylinder.
6. Return complete assembly to HAAS Automation.
INSTALLATION
7. Install cylinder with cylinder rod extended from top of column.
NOTE:
Cylinder rod should pass through column bracket and spindle head bracket. Cylinder body must rest in column
Summary of Contents for VF-SERIES
Page 180: ...1 15 96 96 8100 177 TABLEOFCONTENTS TECHNICAL REFERENCE SERVICE M A N U A L VF SERIES ...
Page 235: ...96 8100 1 15 96 232 VF SERIES S E R V I C E M A N U A L ASSEMBLY DRAWINGS VF 1 COLUMN ...
Page 237: ...96 8100 1 15 96 234 VF SERIES S E R V I C E M A N U A L ASSEMBLY DRAWINGS VF 1 LEADSCREW ...
Page 239: ...96 8100 1 15 96 236 VF SERIES S E R V I C E M A N U A L ASSEMBLY DRAWINGS VF 3 COLUMN ...
Page 241: ...96 8100 1 15 96 238 VF SERIES S E R V I C E M A N U A L ASSEMBLY DRAWINGS VF 3 LEADSCREW ...
Page 245: ...96 8100 1 15 96 242 VF SERIES S E R V I C E M A N U A L ASSEMBLY DRAWINGS 3 4 2 1 ...