GPM-8310 User Manual
220
Note
• Set how each bit in the condition register must
change to trigger the setting of an event.
• For information about the condition register, see
Appendix,"Status system" at page 239.
:STATus:QENable
Description
Sets or returns whether messages other than errors
will be stored to the error queue (ON) or not
(OFF).
Syntax
:STATus:QENable {<Boolean>|OFF|ON}
Query Syntax
:STATus:QENable?
Parameter
<Boolean>0 OFF
<Boolean>1 ON
Return parameter 0
Function is off.
1
Function is on.
Example
:STATUS:QENABLE ON
:STATUS:QENABLE?
-> :STATUS:QENABLE 1
:STATus:QMESsage
Description
Sets or returns whether message information will
be attached to the response to the STATus:ERRor?
query (ON/OFF).
Syntax
:STATus:QMESsage {<Boolean>|OFF|ON}
Query Syntax
:STATus:QMESsage?
Parameter
<Boolean>0 OFF
<Boolean>1 ON
Return parameter 0
Function is off.
1
Function is on.
Set
Query
Set
Query
Summary of Contents for GPM-8310
Page 1: ...Digital Power Meter GPM 8310 USER MANUAL Rev A ISO 9001 CERTIFIED MANUFACTURER ...
Page 74: ...GPM 8310 User Manual 74 3 Press Config soft key to Enter SYSTEM CONFIG setting screen ...
Page 221: ...COMMAND OVERVIEW 221 Example STATUS QMESSAGE ON STATUS QMESSAGE STATUS QMESSAGE 1 ...
Page 239: ...APPENDIX 239 Status system The diagram below is a description of the status system ...
Page 243: ...APPENDIX 243 Dimensions Units mm ...