COMMAND OVERVIEW
201
URMN
Rectified mean voltage Urmn
UAC
AC voltage component Uac
[Vac]
IRMS
True rms current Irms
IMN
Rectified mean current
calibrated to the rms value
Imn
IDC
Simple current average Idc
[Idc]
IRMN
Rectified mean current Irmn
IAC
AC current component Iac
[Iac]
UK
Rms voltage of harmonic
order k U(k)
[V]
IK
Rms current of harmonic
order k I(k)
[A]
PK
Active power of harmonic
order k P(k)
[P]
LAMBDAK
Power factor of harmonic
order k
λ
(k)
PHIK
Phase difference between the
voltage and current of
harmonic order k
φ
(k)
PHIUk
Phase difference between
harmonic voltage U(k) and
the fundamental wave U(1)
φ
U(k)
PHIIk
Phase difference between
harmonic current I(k) and
the fundamental wave I(1)
φ
I(k)
UHDFk
Harmonic distortion factor of
voltage Uhdf(k)
IHDFk
Harmonic distortion factor of
current Ihdf(k)