GPM-8310 User Manual
210
3
P
4
PHIU
5
PHII
6
UHDF
7
IHDF
8
PHDF
:NUMeric:LIST:CLEar
Description
Clears numeric data output items (sets the items to
NONE).
Syntax
:NUMeric:LIST:CLEar {ALL|<NRf>[,<NRf>]}
Parameter
ALL
Clear all items.
1st <NRf>
1 to 8 (the number of the first item to
clear)
2nd <NRf> 1 to 8 (the number of the last item to
clear)
Example
:NUMERIC:LIST:CLEAR ALL
Note
If the 2nd <NRf> is omitted, the output item specified
by the first and all following output items (up to
number 8) are cleared.
:NUMeric:LIST:DELete
Description
Deletes numeric data output items.
Syntax
:NUMeric:LIST:DELete {<NRf>[,<NRf>]}
Parameter
1st <NRf>
1 to 50 (the number of the first item to
delete)
2nd <NRf> 1 to 50 (the number of the last item to
delete)
Set
Set