8.4 Error messages of the controller
No. Fault
Cause
Remedy
1
Pre-empty signal
NaClO
2
NaClO
2
level in tank too low
Refill tank
2
HCl
HCl level in tank too low
3
Empty signal
NaClO
2
NaClO
2
tank empty
4
HCl
HCl tank empty
5
Dosing controller
NaClO
2
Dosing controller incorrectly set
Dosing controller defective
Readjust controller
Replace controller
6
Dosing controller
HCl
7
Level
"Max-Max"
Solution tank: ClO
2
overflow level reached
Check "Max" contact
8
Level
"Min-Min"
Solution tank: ClO
2
dry-run level reached
Check "Min" contact
Check dosing quantity of the pump
Check system status "ON/OFF"
9
Flow
Bypass water
"Min"
Bypass water too low
Increase flow of bypass water
10
Flow
Bypass water
"Max"
Bypass water too high
Reduce flow of bypass water
11
Fault gas warning device
Gas alarm
Eliminate leakage
12
------------------------
-----------------------------------
--------------------------------------
13
Open-circuit at current output
Cable broken
Replace cable
14
Hall sensor
defective
HCl
Cable broken, component defective
Exchange cable or component
15
NaClO
2
16
H
2
O
17
Voltage
24 VDC, too large
Controller defective
Check controller
18
24 VDC, too small
Fuse SI 12 defective
Replace fuse
19
15 VDC, too large
Controller defective
Check controller
20
15 VDC, too small
Fuse SI 9 defective
Replace fuse
21
-15 VDC, too large
Controller defective
Check controller
22
-15 VDC, too small
Fuse SI 9 defective
Replace fuse
23
8 VDC, too large
Controller defective
Check controller
24
8 VDC, too small
Fuse SI 11 defective
Replace fuse
25
12 VDC, too large
Controller defective
Check controller
26
12 VDC, too small
Fuse SI 11 defective, inputs overloaded
Replace fuse, check connection
27
-12 VDC, too large
Controller defective
Check controller
28
-12 VDC, too small
Fuse SI 11 defective
Replace fuse
29
Reactor temperature too high
Dilution water too low, H
2
O pump defective
Check H
2
O setting of the pump,
replace pump
30
Reactor temperature rise too high
Dilution water too low, H
2
O pump defective
31
Battery in PLC exhausted
Battery exhausted
Replace battery
32
Dosing controller
H
2
O
Dosing controller incorrectly set, dosing
controller defective
Readjust controller
Replace controller
33
Preliminary H
2
O
tank
"Max-Max"
Overflow level in preliminary tank for H
2
O is
reached
Check float switch in tank
34
Flow HCl min
Dosing quantity too low
Check dosing pump or quantity
35
Flow HCl max
Dosing quantity too high
36
Flow NaClO
2
min
Dosing quantity too low
37
Flow NaClO
2
max
Dosing quantity too high
38
Flow H
2
O
Dilution min.
Dosing quantity too low
39
Flow H
2
O
Dilution max.
Dosing quantity too high
40
Fault level ClO
2
Level switch on solution tank defective
Check level switch
41
Fault level HCl
Level switch of suction line defective
42
Fault level NaClO
2
43
Fault level H
2
O
44
Open-circuit in temperature sensor
Temperature sensor defective
Replace sensor
45
Short-circuit
Short-circuit
Check controller
46
Fault bypass water flow
Leakage in solenoid valve
Replace solenoid valve
47
Fault: only manual mode possible
"Manual" mode has been selected, although
the system has been started in automatic
mode
When "Manual control" is selected,
start the system in manual mode
Summary of Contents for Oxiperm OCD-164
Page 2: ...2...
Page 247: ...Fran ais FR 247 4 crou filtre PVC gris...
Page 422: ...RU 422 10 10...
Page 431: ...RU 431 10 5 5 2 1 5 5 6 5 6 1 5 6 1 TM04 8202 4510 50 60 6 20 11 1D O2 O...
Page 432: ...RU 432 5 6 2 1 2 3 20 20 4 11 4 5 4 4 5 4 6 5 6 5 6 TM04 8203 4510 1 20 2 3 4 5 6...
Page 526: ...526...