English (GB)
52
11.2 Load unit for booster pump
The booster pump is connected to the controller of the system via
a load unit.
Fig. 41
Load unit for booster pump
Fig. 42
Terminal connection diagram load unit (booster pump)
11.3 Hose connections/hose
Fig. 43
Hose connection
Fig. 44
Connection screwing for external booster pump
11.4 Gas sensor and gas warning device
The gas sensor can be mounted at the rear of the system
underneath the reactor. The required fastening screw
(countersunk screw M6x20) is included in the mounting material
of the system.
T
M
04
82
3
2
45
1
0
Pos. Description
1
Motor-protective circuit breaker
The nominal current of the pump is adjusted at the
motor-protective circuit breaker, see data sheet of
booster pump.
2
Connection cable
The load unit is connected to the controller of the system.
Terminal 22 = L, terminal 23 = N, terminal 24 = PE
Note
If a system with bypass for the external booster
pump is selected, observe the following table for the
selection of the load unit.
Caution
When adjusting the motor-protective circuit breaker,
observe the nominal current of the dosing pump.
Pump type Electrical data
Product No.
CR 1-3
CR 1-5
CR 1-7
1.6 - 2.5 A, 230 V, 50/60 Hz 96728835 (535-50)
1.6 - 2.5 A, 115 V, 50/60 Hz 96728836 (535-51)
CR 1-9,
CR 1-11
2.5 - 4.0 A, 230 V, 50/60 Hz 96728837 (535-52)
2.5 - 4.0 A, 115 V, 50/60 Hz 96728838 (535-53)
TM
04
8
233
45
10
///
3(
89:
$
$
.
0
3(
///
3(
89:
$
$
.
0
3(
Hose connection, DN 20
Product No.
Hose connection DN 20 - ID 25 mm
with 2 hose clamps.
96727534
(529-050)
T
M
04
82
34
45
10
Connection screwing
Product No.
Connection screwing for external
booster pump Rp 1" AG - ID 25 mm
with 2 hose clamps.
96727536
(529-051)
T
M
04
82
35
45
10
PVC hose
Length
Product No.
PVC hose, ID 25
mm, PN 6
5 m
95700198
(526-030/5)
10 m
95700852
(526-030/10)
25 m
95729449
(526-030/25)
Note
Max. system pressure for PVC hose 6 bar.
For a higher system pressure, install a PVC pipe (DN
16).
Description
Product No.
Gas sensor
91835237
(314-011)
Conex DIS-G gas warning unit
96644515
(307-2000)
Caution
Observe the installation and operating instructions of
the Conex DIS-G gas warning unit or the 314 gas
sensor.
Note
The gas sensor cannot be connected directly to the
controller of the system. A gas warning unit is
required in addition. Cabling is carried out on site.
'1
º
5
S
º
Summary of Contents for Oxiperm OCD-164
Page 2: ...2...
Page 247: ...Fran ais FR 247 4 crou filtre PVC gris...
Page 422: ...RU 422 10 10...
Page 431: ...RU 431 10 5 5 2 1 5 5 6 5 6 1 5 6 1 TM04 8202 4510 50 60 6 20 11 1D O2 O...
Page 432: ...RU 432 5 6 2 1 2 3 20 20 4 11 4 5 4 4 5 4 6 5 6 5 6 TM04 8203 4510 1 20 2 3 4 5 6...
Page 526: ...526...